Person:
GÜNDOĞMUŞ, CEMAL AYDIN

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Organizational Unit

Job Title

Last Name

GÜNDOĞMUŞ

First Name

CEMAL AYDIN

Name

Search Results

Now showing 1 - 2 of 2
  • Publication
    Laryngeal Framework Surgical Anatomy: A Radiological Study
    (Mosby Inc., 2021) GÜNDOĞMUŞ, CEMAL AYDIN; Şahin A., Gündoğmuş C.A., Üçkuyulu E.İ., Oysu Ç., Enver N.
    Purpose: Awareness of variations in laryngeal anatomy among different age and gender groups is crucial during laryngeal framework surgery. The aim of this study is to demonstrate the relationship between gender and laryngeal radiologic morphometrics among different age groups and the applicability of important anatomical landmarks of laryngeal surgery. Methods: Laryngeal images of 180 adult patients older than 18 years of age were obtained by computed tomography and assessed. A total of 11 measurements of important laryngeal landmarks were taken from the patients’ computed tomography images. Results were subgrouped according to gender and age, and these groups were compared for each measurement. Results: The majority of laryngeal measurements obtained in the study were higher in males than females, with the exception of the interlaminar angle. The mean interlaminar angle value was 88.27°± 14.99 for males and 103.04°± 14.81 for females (P <0.005). The distance from the anterior commissure to the inferior border of the thyroid cartilage was 10.46 ± 2.5 mm for males and 7.72 ± 1.9 mm for females. The anterior commissure locates slightly higher than the midpoint of the distance from the thyroid notch to the thyroid inferior border. The shortest distance between the muscular process of the arytenoid cartilage and the thyroid cartilage was found to be 9.60 ± 3.47 mm for males and 7.72 ± 2.33 mm for females (P <0.001). Conclusion: Observation of obvious diversities in the size and distance of the important laryngeal structures between the gender groups is an important factor to be considered for successful laryngeal framework surgery. Also, using the midpoint of the thyroid cartilage as a landmark for anterior commissure is a practical method during surgery, especially for thyroplasty. © 2021 The Voice Foundation
  • Publication
    Long-term results and comparison of flow re-direction endoluminal device and pipeline embolization device in endovascular treatment of intracranial carotid aneurysms *
    (SAGE PUBLICATIONS INC) GÜNDOĞMUŞ, CEMAL AYDIN; Gundogmus, Cemal A.; Sabet, Soheil; Baltacioglu, Nurten A.; Tureli, Derya; Bayri, Yasar; Baltacioglu, Feyyaz
    Objective This study aims to compare the efficacy, safety, and long-term outcomes of two flow diverters, i.e., pipeline embolization device and flow re-direction endoluminal device, in the treatment of distal carotid aneurysms. Methods A total of 138 patients with 175 aneurysms were included from February 2012 to September 2019. Ninety-nine aneurysms were treated with flow re-direction endoluminal device and 76 with pipeline embolization device. Angiographic follow-ups were at the 6th, 12th, 24th, 36th, and 60th months; the O'Kelly-Marotta grading scale was used to assess aneurysms occlusion. Outcomes of two devices were compared; possible associations regarding patient characteristics, aneurysm properties, treatment details, and adverse events were evaluated. Results The mean follow-up period was 33 months, with 10 patients lost to follow-up. Occlusion rates at the 6th and 12th months and during the last follow-up were similar for flow re-direction endoluminal device (81%, 84%, and 90%) and pipeline embolization device (82%, 85%, and 93%). Occlusion rates were also similar after stand-alone use without coiling. There was no significant difference regarding adverse event rates with a 10.9% overall complication rate, 3.6% mortality, and 0.7% permanent morbidity. All the mortality and morbidity were related to hemorrhagic complications. Device deployment failure was observed with five flow re-direction endoluminal devices and two pipeline embolization devices, whereas two severe in-stent stenoses occurred with each device. Conclusions Both flow re-direction endoluminal device and pipeline embolization device are feasible and effective in flow diversion of distal internal carotid artery aneurysms, with similar adverse events rates and aneurysm occlusion success. Aneurysm occlusion rates increase with time, while the presence of an integrated branch significantly decreases treatment success.