Person:
ÖZGÜL, BAHAR

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

ÖZGÜL

First Name

BAHAR

Name

Search Results

Now showing 1 - 2 of 2
  • PublicationOpen Access
    Reliability of balance evaluation using Pedalo®-Sensomove Balance device in healthy young individuals
    (2022-11-25) GÜNAY YAZICI, CANAN; ÖZEN BERKOL, TUĞÇE; ÖZGÜL, BAHAR; KURU ÇOLAK, TUĞBA; SARI, ZÜBEYİR; Günay Yazıcı C., Özen Berkol T., Özgül B., Kuru Çolak T., Sarı Z.
    Purpose: It is important to assess the integrity of the balance system to predict individual balance and coordination abilities. MarBES is a device consisting of 9 led scales and 4 pressure sensor systems developed to evaluate and improve balance and coordination as a TÜBİTAK 3001 project. Weight data is estimated from pressure sensors located in 4 different corners and a score is calculated with computer software for the individual\"s center of gravity (Centre of pressure X, Y) and the amount of deviation from the center for each axis.. The aim of this study is to examine the test-retest reliability of the MarBES device. Methods: Double-leg and single-leg (eyes open-closed) tests were applied to healthy young adult participants for balance testing on the MarBES device. Weight transfer to the target surface was measured for assessment of the participants coordination performance. Participants rested for 10 minutes and all measurements were repeated by the same evaluator. The obtained data were recorded and the reliability of the measurements was evaluated with Pearson correlation analysis. Results: A total of 33 healthy young individuals (24 F; 9 M) with a mean age of 21±0.96 years were included in the study. In the correlation analysis, there was a strong correlation in all measurement parameters of the MarBES device except for X axis measurements of right leg (eyes open) and double leg eyes closed (p<0.005). Conclusion: Objective evaluation of balance and coordination parameters is very important in rehabilitation. Resulde of the study showed that the MarBES device developed by the researchers is a reliable method for the evaluation of balance and coordination in healthy young individuals. Keywords: Balance, Coordination, Rehabilitation, Reliability
  • Publication
    The application of matrix rhythm therapy as a new clinical modality in burn physiotherapy programmes
    (ELSEVIER SCI LTD, 2014) ÖZGÜL, BAHAR; Sari, Zubeyir; Polat, Mine Gulden; Ozgul, Bahar; Aydogdu, Onur; Camcioglu, Burcu; Acar, Ahmet Hakan; Yurdalan, Saadet Ufuk
    Purpose: The aim of the present study was to investigate the use of matrix rhythm therapy (MRT) as one of the electrotherapeutic modalities in clinics. Methods: This study was carried out in the Burn and Wound Treatment Department of Dr. Lutfi Kirdar Kartal Education and Research Hospital in Istanbul between October 2010 and August 2011. A treatment protocol including whirlpool, MRT and exercise was applied to a group of patients who had burn injury of upper extremity. The evaluation of each patient included assessment of pain, range of motion, muscle strength, skin flexibility and sensory function at pre- and post-treatment. Results: There was no significant difference in values of pain, muscle strength and flexibility between pre- and post-treatment assessments (p > 0.05). A significant increase was found in the range of motion and sensory function at pre-treatment according to post-treatment (p < 0.01). Conclusion: The usage of MRT in order to maintain and improve the range of motion and to minimise the development of scar tissue was investigated in this study. We suggest conducting randomised controlled studies that carry out a comparison of the MRT with other treatment modalities with more cases and investigate the long-term effects of MRT. (C) 2013 Elsevier Ltd and ISBI. All rights reserved.