Publication:
EFFECT OF THE GEOMETRICAL PARAMETERS IN A DOMESTIC BURNER WITH CRESCENT FLAME CHANNELS FOR AN OPTIMAL TEMPERATURE DISTRIBUTION AND THERMAL EFFICIENCY

dc.contributor.authorÖZDEMİR, MEHMED RAFET
dc.contributor.authorsSener, Ramazan; Ozdemir, Mehmed R.; Yangaz, Murat U.
dc.date.accessioned2022-03-14T09:10:03Z
dc.date.available2022-03-14T09:10:03Z
dc.date.issued2019-12-02
dc.description.abstractDomestic cookers are common tools of house appliances in the world and they have significant share in global energy consumption. Therefore, a small amount of improvement in efficiency would result in a huge drop in total energy and resource activity. This study aims at presenting numerically the thermal efficiency of a domestic burner with crescent-shaped flame channels by changing the distance from the cooker to the burner head and the diameter of the burner. The energy efficiency parameter was evaluated analyzing temperature distribution along the bottom surface of the cooker and unburnt HC, CO and NO emissions. Simulations have been carried out with methane as fuel for three different diameter and distance parameters. The results showed that the temperature on the surface and the emission values of unburnt CO, NO and HC decreased with increasing the cooker diameter and distance parameter.
dc.identifier.doi10.18186/thermal.654303
dc.identifier.issn2148-7847
dc.identifier.urihttps://hdl.handle.net/11424/242680
dc.identifier.wosWOS:000500729400003
dc.language.isoeng
dc.publisherYILDIZ TECHNICAL UNIV
dc.relation.ispartofJOURNAL OF THERMAL ENGINEERING
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCombustion
dc.subjectCFD
dc.subjectDomestic Burner
dc.subjectCooker
dc.subjectEmissions
dc.subjectFuel
dc.subjectTURBULENT COMBUSTION
dc.subjectGAS-BURNER
dc.subjectFUEL
dc.subjectLPG
dc.subjectSIMULATION
dc.subjectEMISSIONS
dc.subjectSTOVE
dc.subjectMODEL
dc.subjectOXIDE
dc.subjectFLOW
dc.titleEFFECT OF THE GEOMETRICAL PARAMETERS IN A DOMESTIC BURNER WITH CRESCENT FLAME CHANNELS FOR AN OPTIMAL TEMPERATURE DISTRIBUTION AND THERMAL EFFICIENCY
dc.typearticle
dspace.entity.typePublication
local.avesis.idaef999d8-ea30-485a-a0ff-7d00234ce297
local.import.packageSS16
local.indexed.atWOS
local.indexed.atSCOPUS
local.journal.numberofpages13
oaire.citation.endPage183
oaire.citation.issue6
oaire.citation.startPage171
oaire.citation.titleJOURNAL OF THERMAL ENGINEERING
oaire.citation.volume5
relation.isAuthorOfPublication0ba9888a-c461-4d55-83da-4114c06d98a8
relation.isAuthorOfPublication.latestForDiscovery0ba9888a-c461-4d55-83da-4114c06d98a8

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Şener et al. - 2019 - EFFECT OF THE GEOMETRICAL PARAMETERS IN A DOMESTIC.pdf
Size:
1.19 MB
Format:
Adobe Portable Document Format

Collections