Publication:
Oxygen reserve index guided oxygen titration in one lung ventilation with low fresh gas flow

dc.contributor.authorSARAÇOĞLU, AYTEN
dc.contributor.authorsSaracoglu, Ayten; Sirzai, Esra Yamansavci; Yildizeli, Bedrettin; Yuksel, Mustafa; Aykac, Zeynep Zuhal
dc.date.accessioned2022-04-25T00:11:58Z
dc.date.available2022-04-25T00:11:58Z
dc.date.issued2021
dc.description.abstractBackground/aim: Continuous oxygen reserve index (ORI) measurement with multiple wave pulse co-oximetry is a noninvasive measurement. The decrease in the ORI trend provides a prediction for the development of hypoxemia and provides information on hyperoxia. Our aim is to determine the effect of ORI-guided oxygen titration on hyperoxemia-mediated morbidity. Materials and methods: Consecutive 120 ASA I-III patients, 18-70 years of age, without severe obstruction or restriction, undergoing one lung ventilation (OLV), were included in the study. Patients were divided into 4 groups. Oxygen titration without ORI monitoring with low-flow anesthesia (1 L/min, Group 1, n = 25) and high-flow anesthesia (4 L/min, Group 2, n = 28). Oxygen titration by ORI monitoring with low flow anesthesia (1 L/min, Group 3, n = 25) and high flow anesthesia (4 L/min, Group 4, n = 25). FiO(2) increased up to 100% if necessary. OLV time, duration of surgery and anesthesia, FiO(2) applied during OLV, oxygen application time (T) over 60%, vital signs, hospital and ICU stay time, and complications were recorded. Results: There was a statistically significant difference in terms of FiO(2) used during OLV (p < 0.05). There was no difference in ORI values (p < 0.05). In Group 3, both PaO2 and SpO(2) were significantly lower than the others both before and during OLV. There was no significant difference in terms of ORI parameters between low flow and high flow anesthesia groups. There was a strong, positive correlation between the duration of hospital stay and FiO(2) used above 80% during OLV. Conclusion: We concluded that ORI-guided thoracic anesthesia may reduce hospital stay and increase patient safety.
dc.identifier.doi10.3906/sag-2009-149
dc.identifier.eissn1303-6165
dc.identifier.issn1300-0144
dc.identifier.pubmed34051711
dc.identifier.urihttps://hdl.handle.net/11424/264000
dc.identifier.wosWOS:000711339600024
dc.languageeng
dc.publisherTUBITAK SCIENTIFIC & TECHNICAL RESEARCH COUNCIL TURKEY
dc.relation.ispartofTURKISH JOURNAL OF MEDICAL SCIENCES
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectOxygen reserve index
dc.subjectthoracic surgery
dc.subjectone lung ventilation
dc.subjectlow flow anesthesia
dc.subjectCOMPLICATIONS
dc.titleOxygen reserve index guided oxygen titration in one lung ventilation with low fresh gas flow
dc.typearticle
dspace.entity.typePublication
local.avesis.id0e8d8a31-7a78-42eb-8b28-70a439eba051
local.import.packageSS39
local.indexed.atWOS
local.journal.numberofpages7
oaire.citation.endPage2419
oaire.citation.issue5
oaire.citation.startPage2413
oaire.citation.titleTURKISH JOURNAL OF MEDICAL SCIENCES
oaire.citation.volume51
relation.isAuthorOfPublicationac82ef6c-8ece-4923-bbc3-2ef67da6f28e
relation.isAuthorOfPublication.latestForDiscoveryac82ef6c-8ece-4923-bbc3-2ef67da6f28e

Files

Collections