Publication:
Prediction of future disposal of end-of-life refrigerators containing CFC-11

dc.contributor.authorÇALLI, BARIŞ
dc.contributor.authorsYazici, Burcu; Can, Zehra S.; Calli, Bans
dc.date.accessioned2022-03-13T12:44:31Z
dc.date.available2022-03-13T12:44:31Z
dc.date.issued2014
dc.description.abstractThe objective of this study was to predict the number of refrigerators containing CFC-11 blown isolation foam and the amount of CFC-11 banked in these refrigerators. By using a Weibull-based survival function, the number of CFC-11 containing and still-functioning refrigerators was estimated to be approximately 1.6 million in 2013 in Turkey. In order to determine the amount of CFC-11 in the isolation foam of these refrigerators, polyurethane (PU) foam samples were taken from a refrigerator manufactured in 1993 and the quantity of CFC-11 was analyzed by a GC-MS. It was determined that 113-195 mg CFC-11/g PU remains in the PU foam depending on the location such as door, sides, top and bottom. Knowing that a mid-sized refrigerator contains 4 kg PU on average, the total amount of PU foam to be disposed of is 6344 tons when the CFC-11 containing refrigerators in Turkey become obsolete in the near future. Furthermore, 717-1237 tons of CFC-11 are expected to be banked in the PU foam of these refrigerators which will exert an equivalent amount of ozone depleting potential (ODP). In addition, the global warming potential will vary between 3.4 and 5.9 million tons of CO2. (C) 2013 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.wasman.2013.09.008
dc.identifier.issn0956-053X
dc.identifier.pubmed24112854
dc.identifier.urihttps://hdl.handle.net/11424/237556
dc.identifier.wosWOS:000329001100020
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofWASTE MANAGEMENT
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCFCs
dc.subjectEnd-of-life refrigerators
dc.subjectGlobal warming
dc.subjectOzone depleting potential
dc.subjectPolyurethane foam
dc.subjectPOLYURETHANE FOAM WASTE
dc.subjectFLUOROCARBONS
dc.subjectAPPLIANCES
dc.subjectRELEASE
dc.titlePrediction of future disposal of end-of-life refrigerators containing CFC-11
dc.typearticle
dspace.entity.typePublication
local.avesis.id8218da43-d2c1-4358-96e6-069b374cb213
local.import.packageSS17
local.indexed.atWOS
local.indexed.atSCOPUS
local.indexed.atPUBMED
local.journal.numberofpages5
oaire.citation.endPage166
oaire.citation.issue1
oaire.citation.startPage162
oaire.citation.titleWASTE MANAGEMENT
oaire.citation.volume34
relation.isAuthorOfPublication2e20fe96-469a-44e0-88b2-e56450a93cf6
relation.isAuthorOfPublication.latestForDiscovery2e20fe96-469a-44e0-88b2-e56450a93cf6

Files

Collections