Publication:
Renal artery stenting in solitary functioning kidneys: Technical and clinical results

dc.contributor.authorBALTACIOĞLU, FEYYAZ
dc.contributor.authorsSahin, S; Cimsit, C; Andac, N; Baltacioglu, F; Tuglular, S; Akoglu, E
dc.date.accessioned2022-03-12T17:21:08Z
dc.date.available2022-03-12T17:21:08Z
dc.date.issued2006
dc.description.abstractObjective: To evaluate the clinical and technical results of renal artery stenting for the treatment of renovascular hypertension and renal failure in patients with solitary functioning kidney. Materials and methods: Fifteen patients with solitary functioning kidney underwent renal artery stenting and were followed up for 12-60 months. Before the procedures, systolic and diastolic blood pressures and serum creatinine levels were measured and the number of antihypertensive drugs was recorded and followed up after stenting. In case of restenosis, either in-stent percutaneous transluminal renal angioplasty or stent-in-stent placement was performed. Results: Primary technical success rate was 100%. One lesion was nonostial while 14 were ostial. Primary patency rates were 100% for 6 months, 92.3% for 12 months, and 69.2% for 24 months. The secondary patency rate at 24 months was 100%. The differences between the baseline and postprocedural values of systolic blood pressures, diastolic blood pressures and the number of antihypertensive drug were statistically significant (P < 0.05), except the values of serum creatinine. Hypertension was cured in 1 (6.7%) patient, improved in 4 (26.6%) and stabilized in 10 (66.7%) patients. Renal function improved in 9 (60%), stabilized in 4 (26.6%), and deteriorated in 2 (13.4%) patients. Minor complication rate was 13.4% and major complication rate was 13.4%. Conclusion: Revascularization of renal artery stenosis using stent in solitary functioning kidneys is a safe and efficient procedure with high primary technical results, low restenosis rates and acceptable complication rates. It has an improving and controlling effect on blood pressure and renal functions. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
dc.identifier.doi10.1016/j.ejrad.2005.05.004
dc.identifier.issn0720-048X
dc.identifier.pubmed15951146
dc.identifier.urihttps://hdl.handle.net/11424/228316
dc.identifier.wosWOS:000235322200020
dc.language.isoeng
dc.publisherELSEVIER IRELAND LTD
dc.relation.ispartofEUROPEAN JOURNAL OF RADIOLOGY
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectsolitary kidney
dc.subjectrenal artery stent
dc.subjectrenal artery stenosis
dc.subjectrenal failure
dc.subjectrevascularization
dc.subjectTRANS-LUMINAL ANGIOPLASTY
dc.subjectFOLLOW-UP
dc.subjectRENOVASCULAR HYPERTENSION
dc.subjectISCHEMIC NEPHROPATHY
dc.subjectBLOOD-PRESSURE
dc.subjectPALMAZ STENT
dc.subjectSTENOSIS
dc.subjectPLACEMENT
dc.subjectREVASCULARIZATION
dc.subjectDISEASE
dc.titleRenal artery stenting in solitary functioning kidneys: Technical and clinical results
dc.typearticle
dspace.entity.typePublication
local.avesis.id4966bee3-fc41-4b38-9e73-8d6a97e9974f
local.import.packageSS17
local.indexed.atWOS
local.indexed.atSCOPUS
local.journal.numberofpages7
oaire.citation.endPage137
oaire.citation.issue1
oaire.citation.startPage131
oaire.citation.titleEUROPEAN JOURNAL OF RADIOLOGY
oaire.citation.volume57
relation.isAuthorOfPublication14b6381a-4f6e-4ff9-92f6-842a481bc163
relation.isAuthorOfPublication.latestForDiscovery14b6381a-4f6e-4ff9-92f6-842a481bc163

Files