Publication:
Developing a wearable device for upper extremity tremors

dc.contributor.authorAKGÜN, GAZİ
dc.contributor.authorGÜNAL, DİLEK
dc.contributor.authorAKÜNER, MUSTAFA CANER
dc.contributor.authorŞEHİRLİ, ÜMİT SÜLEYMAN
dc.contributor.authorsYildiz S. D., AKGÜN G., GÜNAL D., Kaplanoglu E., AKÜNER M. C., ŞEHİRLİ Ü. S.
dc.date.accessioned2024-07-01T12:43:57Z
dc.date.available2024-07-01T12:43:57Z
dc.date.issued2024-05-31
dc.description.abstractObjective: This project aims to develop a wearable device to suppress both the essential and resting tremor and investigate its effectiveness. Materials and Methods: This study details the development and assessment of a wearable device for upper extremity tremors. The wearable device underwent a comprehensive design and a prototype was produced with a 3D-printer. To refine the functionality of the prototype, a motor that mimics tremor was attached to a 3D-printed prototype. Then, the printed prototype was applied to the hand model, and tested its effectiveness for tremor suppressing. The wearable device was further investigated on patients with essential tremor and Parkinson`s disease seeking treatment at Neurology Clinics. We recorded the tremor data and processed and visualized the recorded data by using the MatLab (version R2021a, MathWorks Inc., USA) software. Results: The wearable device effectively decreased the tremors both during the simulation phase and the patient testing phase. The data from the wearable device revealed a notable decrease in the amplitude of the tremor. This decrease signifies an achievement of tremor suppression. Conclusion: The prototype of the wearable device signifies a remarkable efficacy in tremor supression. It holds promise for being a potential solution to alleviate the tremor symptoms of essential tremor and Parkinson`s disease patients.
dc.identifier.citationYildiz S. D., AKGÜN G., GÜNAL D., Kaplanoglu E., AKÜNER M. C., ŞEHİRLİ Ü. S., "Developing a wearable device for upper extremity tremors", Marmara Medical Journal, cilt.37, sa.2, ss.157-165, 2024
dc.identifier.doi10.5472/marumj.1483038
dc.identifier.endpage165
dc.identifier.issn1019-1941
dc.identifier.issue2
dc.identifier.startpage157
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85196164885&origin=inward
dc.identifier.urihttps://hdl.handle.net/11424/297137
dc.identifier.volume37
dc.language.isoeng
dc.relation.ispartofMarmara Medical Journal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectTemel Tıp Bilimleri
dc.subjectMedicine
dc.subjectHealth Sciences
dc.subjectFundamental Medical Sciences
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectTIP, GENEL & DAHİLİ
dc.subjectClinical Medicine (MED)
dc.subjectCLINICAL MEDICINE
dc.subjectMEDICINE, GENERAL & INTERNAL
dc.subjectGenel Tıp
dc.subjectGeneral Medicine
dc.subjectEssential Tremor
dc.subjectParkinson`s Disease
dc.subjectWearable device
dc.titleDeveloping a wearable device for upper extremity tremors
dc.typearticle
dspace.entity.typePublication
local.avesis.ide972cecb-a057-4972-a38c-4b48b7fa8261
local.indexed.atSCOPUS
relation.isAuthorOfPublication4cca1569-333a-440f-9f9e-7cf897217af2
relation.isAuthorOfPublication35469359-99cb-42f9-9a48-bbe160fee6e2
relation.isAuthorOfPublication6341ebb9-2138-475b-b673-cc0bc796a0c0
relation.isAuthorOfPublication947be220-92d1-428d-bc90-7806465712dd
relation.isAuthorOfPublication.latestForDiscovery4cca1569-333a-440f-9f9e-7cf897217af2

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
1.71 MB
Format:
Adobe Portable Document Format

Collections