Publication:
DETERMINATION OF THE SHEAR-STRENGTH REQUIREMENT FOR THE ADHESIVE USED BETWEEN CAVITY FILLING MATERIALS AND DENTIN

dc.contributor.authorEKİCİ, BÜLENT
dc.contributor.authorsEKICI, B; ALTINTAS, S
dc.date.accessioned2022-03-12T16:57:05Z
dc.date.available2022-03-12T16:57:05Z
dc.date.issued1993
dc.description.abstractA finite element technique is used to examine the stress distribution in a human first premolar with and without cavity preparation by using 2- and 3-dimensional models. The effects of different adhesive materials as cavity fillers on stress distribution are investigated. Since one of the most important factors affecting the success of a restoration process in clinical applications is the strength of the adhesive, the shear stresses obtained from numerical research are investigated in detail. Although in clinical applications the interfacial space between filling material and dentine is very important, it is assumed to be negligible here since it will not help in calculating the shear strength requirements of the adhesive. Therefore, one of the assumptions used throughout the analysis is that there are no interfacial spaces. In order to determine the effects of adhesive, all possible situations are included in the analyses. Different adhesives and different cavity filling materials are used in the model. In addition to these conditions, the effects of spring support conditions and temperature are also considered in the study.
dc.identifier.doi10.1016/0965-9978(94)90002-7
dc.identifier.issn0965-9978
dc.identifier.urihttps://hdl.handle.net/11424/226877
dc.identifier.wosWOS:A1993NF95600002
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofADVANCES IN ENGINEERING SOFTWARE
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectFIRST PREMOLAR
dc.subjectFEM ANALYSIS
dc.subjectDENTAL RESTORATION
dc.subjectADHESIVES FOR TEETH
dc.subjectSHEAR STRENGTH OF DENTAL ADHESIVES
dc.subjectSTRESS-ANALYSIS
dc.subjectTEETH
dc.titleDETERMINATION OF THE SHEAR-STRENGTH REQUIREMENT FOR THE ADHESIVE USED BETWEEN CAVITY FILLING MATERIALS AND DENTIN
dc.typearticle
dspace.entity.typePublication
local.avesis.id7a42757f-1709-4fca-878e-3775f387ef15
local.import.packageSS17
local.indexed.atWOS
local.indexed.atSCOPUS
local.journal.numberofpages7
oaire.citation.endPage93
oaire.citation.issue2
oaire.citation.startPage87
oaire.citation.titleADVANCES IN ENGINEERING SOFTWARE
oaire.citation.volume18
relation.isAuthorOfPublicationbfa2c25f-3c5b-4469-a10f-34f036177bc1
relation.isAuthorOfPublication.latestForDiscoverybfa2c25f-3c5b-4469-a10f-34f036177bc1

Files

Collections