Publication:
Cyclic fatigue resistance and shaping ability of heat-treated nickel-titanium instruments after repeated use

dc.contributor.authorTÜRKAYDIN, DİLEK
dc.contributor.authorsKamali, S. G.; Turkaydin, D.
dc.date.accessioned2022-03-12T22:55:11Z
dc.date.available2022-03-12T22:55:11Z
dc.date.issued2021
dc.description.abstractAims: To evaluate the effect of multiple-use and sterilization on cyclic fatigue and shaping ability of heat-treated nickel-titanium (NiTi) rotary instruments. Methods: A total of 120 acrylic blocks with S-shaped canals were photographed and prepared by HyFlex CM, ProTaper Next, and Twisted File. Ten new sets of each rotary instruments were used for four times. The autoclaving process was repeated after each use. Pre- and post instrumentation images were superimposed. The amount of resin removal and canal transportation by each system was measured in eleven different points. Instruments were subsequently subjected to a cyclic fatigue test in a double-curved artificial canal. The means and standard deviations of the number of cycles to failure (NCF) were calculated and statistically analyzed (P < 0.05). Results: No fractures occurred during the shaping of the simulated canals. The ProTaper Next removed the greatest amount of resin, whereas the Twisted File had the lowest values at all levels. Repeated clinical use and sterilization resulted in a decrease in the resin removal at most levels in Twisted File and ProTaper Next. In terms of canal transportation, an increase in a limited number of levels was detected after repeated use of all rotary files. Twisted File had the greatest cyclic fatigue resistance, followed by HyFlex CM and ProTaper Next (P < 0.05). Conclusions: The effects of repeated use and autoclaving on the cyclic fatigue resistance of HyFlex CM, ProTaper Next, and Twisted File were not significant. Canal transportation increased mostly in the apical region. The amount of resin removal decreased as the number of use increased for ProTaper Next and Twisted File instruments.
dc.identifier.doi10.4103/njcp.njcp_166_20
dc.identifier.issn1119-3077
dc.identifier.pubmed33605916
dc.identifier.urihttps://hdl.handle.net/11424/236675
dc.identifier.wosWOS:000623686500016
dc.language.isoeng
dc.publisherWOLTERS KLUWER MEDKNOW PUBLICATIONS
dc.relation.ispartofNIGERIAN JOURNAL OF CLINICAL PRACTICE
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCyclic fatigue
dc.subjectmultiple-use
dc.subjectrepeated use
dc.subjectshaping ability
dc.subjecttransportation
dc.titleCyclic fatigue resistance and shaping ability of heat-treated nickel-titanium instruments after repeated use
dc.typearticle
dspace.entity.typePublication
local.avesis.id870b63c1-66cd-40c9-84bc-2787db64a599
local.import.packageSS17
local.indexed.atWOS
local.indexed.atSCOPUS
local.indexed.atPUBMED
local.journal.numberofpages7
oaire.citation.endPage253
oaire.citation.issue2
oaire.citation.startPage247
oaire.citation.titleNIGERIAN JOURNAL OF CLINICAL PRACTICE
oaire.citation.volume24
relation.isAuthorOfPublication2e624b23-4a1c-45df-ace0-fe6ae918e8c5
relation.isAuthorOfPublication.latestForDiscovery2e624b23-4a1c-45df-ace0-fe6ae918e8c5

Files

Collections