Person:
BALTACIOĞLU, FEYYAZ

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Organizational Unit

Job Title

Last Name

BALTACIOĞLU

First Name

FEYYAZ

Name

Search Results

Now showing 1 - 4 of 4
  • Publication
    Stent-assisted coil embolization of challenging intracranial aneurysms: initial and mid-term results with low-profile ACCLINO devices
    (SPRINGER WIEN, 2016) TÜRELİ, DERYA; Tureli, Derya; Sabet, Soheil; Senol, Serkan; Andac, Nurten; Donmez, Halil; Geyik, Serdar; Baltacioglu, Feyyaz; Cekirge, Saruhan
    Stent-assisted coiling using low-profile, self-expandable and retrievable stents is a valid option in endovascular treatment of challenging intracranial aneurysms. This study aims to evaluate the feasibility and efficacy of ACCLINO 1.9 F and ACCLINO Flex stent systems, designed for use as adjunctive products in coil embolization of intracranial aneurysms. Case files of 47 patients, and 52 aneurysms in total, treated with at least one ACCLINO 1.9 F or ACCLINO Flex stent were retrospectively evaluated. Technical success, complications, and angiographic outcomes were assessed based on immediate post-procedural controls along with 6th and 12th month angiograms. Mechanical untoward event rate, including asymptomatic complications, is 9.6 % (five out of 52 aneurysms). Failed dual-stenting attempt rate is 15.4 % (two out of 13). Overall procedure-related morbidity is 4.2 % with no neurologic sequelae. Initial occlusion rate is 90.4 % (47 aneurysms). One patient had residual filling in the aneurysm neck, which was stable throughout follow-up. The remaining four cases had spontaneous follow-up occlusion. Recanalization rate at 6th month is 2.1 % with one aneurysm requiring retreatment. One patient was lost to follow-up. There is no mortality associated with treatment. Stent-assisted coil embolization with ACCLINO stents in single or dual configurations is a feasible treatment option for challenging intracranial aneurysms. Follow-up results are encouraging; techniques were effective in complex cases and there were no clinically significant adverse outcomes.
  • Publication
    Is any landmark reliable in vertebral enumeration? A study of 3.0-Tesla lumbar MRI comparing skeletal, neural, and vascular markers
    (ELSEVIER SCIENCE INC, 2014) TÜRELİ, DERYA; Tureli, Derya; Ekinci, Gazanfer; Baltacioglu, Feyyaz
    Purpose: This study aimed to determine the reliability of the iliolumbar ligament (ILL), 12th costa, aortic bifurcation (AB), Tight renal artery (RRA), and conus medullaris (CM) for numbering of vertebral segments. Subjects and methods: Five hundred five patients underwent routine lumbar MRI examinations including a cervicothoracic sagittal scout and T1 and T2-weighted sagittal and axial turbo spin echo images. Images were evaluated by two radiologists separately. Results: The identifiability of ILL and 12th costa were 85.7% and 48.1%. AB, RRA, and CM were located more caudally in lumbarized S1 and more cranially in sacralized L5 cases. Conclusion: Landmarks suggested by previous studies are not reliable alternatives to cervicothoracic scout images due to wide ranges of distribution and inconsistencies in identification. (C) 2014 Elsevier Inc. All rights reserved.
  • PublicationOpen Access
    Unexpected radiation pneumonitis after SIRT with significant decrease in DLCO with internal radiation exposure: a case report
    (BMC, 2020-12) TÜRELİ, DERYA; Kesim, Selin; Ones, Tunc; Eryuksel, Emel; Baltacioglu, Feyyaz; Tureli, Derya; Ozguven, Salih; Erdil, Tanju Yusuf
    Background In the last years, Selective Internal Radiation Therapy (SIRT), using biocompatible Yttrium-90 (90Y) labeled microspheres have emerged for the treatment of malignant hepatic tumors. Unfortunately, a significant part of 90Y-labeled microspheres may shunt to the lungs after intraarterial injection. It can be predictable by infusing technetium-99 m-labeled macro-aggregated albumin particles through a catheter placed in the proper hepatic artery depending on the lobe to be treated with performing a quantitative lung scintigraphy. Radiation pneumonitis (RP) can occur 1 to 6 months after the therapy, which is a rare but severe complication of SIRT. Prompt timing of steroid treatment is important due to its high mortality rate. On the other hand, pulmonary diffusion capacity measured by carbon monoxide (DLCO) is an excellent way to measure the diffusing capacity because carbon monoxide is present in minimal amount in venous blood and binds to hemoglobin in the same manner as oxygen. Some authors reported that the most consistent changes after radiation therapy (RT) are recorded with this quantitative reproducible test. The relationship between the proportional reductions in DLCO and the severity of RP developing after this therapy may prove to be clinically significant. Case presentation We herein present a patient who developed RP after SIRT that could be quantified using DLCO. To the best of our knowledge, this case is the first who developed unexpected RP after SIRT with significant decrease in DLCO with internal radiation exposure. Conclusions RP is a very rare complication and may lead to a fatal outcome. Decline in DLCO could be a valuable parameter for follow-up and to identify potential candidates for RP and could be also another trigger for administration of steroid therapy with prompt timing in this patient group.
  • Publication
    Long-term results and comparison of flow re-direction endoluminal device and pipeline embolization device in endovascular treatment of intracranial carotid aneurysms *
    (SAGE PUBLICATIONS INC) GÜNDOĞMUŞ, CEMAL AYDIN; Gundogmus, Cemal A.; Sabet, Soheil; Baltacioglu, Nurten A.; Tureli, Derya; Bayri, Yasar; Baltacioglu, Feyyaz
    Objective This study aims to compare the efficacy, safety, and long-term outcomes of two flow diverters, i.e., pipeline embolization device and flow re-direction endoluminal device, in the treatment of distal carotid aneurysms. Methods A total of 138 patients with 175 aneurysms were included from February 2012 to September 2019. Ninety-nine aneurysms were treated with flow re-direction endoluminal device and 76 with pipeline embolization device. Angiographic follow-ups were at the 6th, 12th, 24th, 36th, and 60th months; the O'Kelly-Marotta grading scale was used to assess aneurysms occlusion. Outcomes of two devices were compared; possible associations regarding patient characteristics, aneurysm properties, treatment details, and adverse events were evaluated. Results The mean follow-up period was 33 months, with 10 patients lost to follow-up. Occlusion rates at the 6th and 12th months and during the last follow-up were similar for flow re-direction endoluminal device (81%, 84%, and 90%) and pipeline embolization device (82%, 85%, and 93%). Occlusion rates were also similar after stand-alone use without coiling. There was no significant difference regarding adverse event rates with a 10.9% overall complication rate, 3.6% mortality, and 0.7% permanent morbidity. All the mortality and morbidity were related to hemorrhagic complications. Device deployment failure was observed with five flow re-direction endoluminal devices and two pipeline embolization devices, whereas two severe in-stent stenoses occurred with each device. Conclusions Both flow re-direction endoluminal device and pipeline embolization device are feasible and effective in flow diversion of distal internal carotid artery aneurysms, with similar adverse events rates and aneurysm occlusion success. Aneurysm occlusion rates increase with time, while the presence of an integrated branch significantly decreases treatment success.