Person:
BALTACIOĞLU, FEYYAZ

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Organizational Unit

Job Title

Last Name

BALTACIOĞLU

First Name

FEYYAZ

Name

Search Results

Now showing 1 - 2 of 2
  • Publication
    Stent-assisted coil embolization of challenging intracranial aneurysms: initial and mid-term results with low-profile ACCLINO devices
    (SPRINGER WIEN, 2016) TÜRELİ, DERYA; Tureli, Derya; Sabet, Soheil; Senol, Serkan; Andac, Nurten; Donmez, Halil; Geyik, Serdar; Baltacioglu, Feyyaz; Cekirge, Saruhan
    Stent-assisted coiling using low-profile, self-expandable and retrievable stents is a valid option in endovascular treatment of challenging intracranial aneurysms. This study aims to evaluate the feasibility and efficacy of ACCLINO 1.9 F and ACCLINO Flex stent systems, designed for use as adjunctive products in coil embolization of intracranial aneurysms. Case files of 47 patients, and 52 aneurysms in total, treated with at least one ACCLINO 1.9 F or ACCLINO Flex stent were retrospectively evaluated. Technical success, complications, and angiographic outcomes were assessed based on immediate post-procedural controls along with 6th and 12th month angiograms. Mechanical untoward event rate, including asymptomatic complications, is 9.6 % (five out of 52 aneurysms). Failed dual-stenting attempt rate is 15.4 % (two out of 13). Overall procedure-related morbidity is 4.2 % with no neurologic sequelae. Initial occlusion rate is 90.4 % (47 aneurysms). One patient had residual filling in the aneurysm neck, which was stable throughout follow-up. The remaining four cases had spontaneous follow-up occlusion. Recanalization rate at 6th month is 2.1 % with one aneurysm requiring retreatment. One patient was lost to follow-up. There is no mortality associated with treatment. Stent-assisted coil embolization with ACCLINO stents in single or dual configurations is a feasible treatment option for challenging intracranial aneurysms. Follow-up results are encouraging; techniques were effective in complex cases and there were no clinically significant adverse outcomes.
  • Publication
    Long-term clinical and angiographic follow-up results of the dual-layer flow diverter device (FRED) for the treatment of intracranial aneurysms in a multicenter study
    (SPRINGER, 2021) BALTACIOĞLU, FEYYAZ; Dinc, Hasan; Saatci, Isil; Oguz, Sukru; Baltacioglu, Feyyaz; Yildiz, Altan; Donmez, Halil; Belet, Umit; Onal, Baran; Andic, Cagatay; Koc, Osman; Kocak, Omer; Koroglu, Mert; Cetin, Mustafa; Cekirge, H. Saruhan
    Purpose Our aim was to determine the long-term safety and efficacy of the Flow Re-Direction Endoluminal Device (FRED) in this multicenter study with prospective design. Materials-method This study included 136 consecutive patients with 155 aneurysms treated between March 2013 and June 2016 in 10 centers. Twenty-two (16.2%) patients presented with rupture of the index aneurysm. Large/giant aneurysms comprised 1/3 of the cohort. Adjuvant coil use during the treatment was 15.5%. The effectiveness measure in the study was the percentage of aneurysms with stable occlusion at follow-up. Results Vascular imaging follow-up was performed at least once in 131/136 (96.3%) patients with 148/155 (95.5%) aneurysms up to 75 months (mean: 37.3 months; median: 36 months according to latest follow-up), and 102/155(65.8%) aneurysms in 90/136 (66.2%) patients had >= 24-month control. According to the latest controls, the overall stable occlusion rate was 91.9% (95% CI, 87.5 to 96.3%). Three out of 148 aneurysms with follow-up were retreated (2%, 95% CI 0.0 to 4.3%). Adverse events were noted in 19/136 (14%, 95% CI, 9 to 21%) patients with a morbidity of 1.5% (95% CI, 0.0 to 3.5%). Mortality was 1/136 (0.7%, 95% CI, 0.02 to 2.2%) and was unrelated to aneurysm treatment. In-stent stenosis (ISS) was detected in 10/131 of the patients with follow-up (7.6%, 95% CI; 3.1 to 12.2%), only one being symptomatic. No adverse events have occurred in any of the patients with follow-up after 24 months, except the one resulting from ISS. Conclusion In the treatment of cerebral aneurysms which were candidates for flow diversion technique, this study showed long-term efficacy of FRED with good safety and occlusion rates.