Person:
DÖRÜCÜ, DOĞANCAN

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Organizational Unit

Job Title

Last Name

DÖRÜCÜ

First Name

DOĞANCAN

Name

Search Results

Now showing 1 - 2 of 2
  • PublicationOpen Access
    A survey study on evaluation and management of nocturnal enuresis in pediatricians and family physicians
    (2023-09-01) ŞEKERCİ, ÇAĞRI AKIN; KÜTÜKOĞLU, MEHMET UMUT; DÖRÜCÜ, DOĞANCAN; TANIDIR, YILÖREN; ÇAM, HAYDAR KAMİL; TARCAN, TUFAN; YÜCEL, SELÇUK; Şekerci Ç. A., Kütükoğlu M. U., Dörücü D., Ergün R., Tanıdır Y., Çam H. K., Tarcan T., Yücel S.
    Objective:Nocturnal enuresis (NE) is one of the most common disorders in pediatric urology, and patients often turn to family physicians (FP) and pediatricians (P) initially. The aim of this study was to understand the awareness, self-confidence and suggestions of physicians regarding the management of NE.Materials and Methods:In this study, 360 FP and family medicine residents (FMR), as well as 280 P and pediatrics residents (PR), were contacted through a cellular phone texting system. A simple multiple-choice questionnaire (Surveymonkey®) consisting of 10 questions was used to gather data. The survey included questions about their experience, training, evaluation, and management of NE.Results:A total of 119 FPs and Ps (18.5%) filled the questionnaire. Thirty (25.21%) of the participants were P, 27 (22.69%) PR, 3 (2.52%) FP and 59 (49.58%) FMR. The rate of physicians who encounter at least 5 children with NE per month is 31.33%. The mean self-confidence in the management of NE was 4.5 out of 10. The self-confidence of pediatricians was significantly higher than that of PR and FMR (p<0.001, p<0.001). Most (n=78, 65.55%) of the participants stated that they received training on EN during medical faculty and 62 (52.10%) during residency. Psychological problems (89.92%), sleep disorders (78.15%), and excessive fluid intake (75.63%) were the most frequently considered factors in etiology. While most responders (75.63%) considered dietary regulation and behavioral interventions as the first-line treatment, 25.21% consult a pediatric urologist and only 1.6% recommend medical treatment.Conclusion:Although FP and P admit they had training on NE, they mostly felt incompetent to manage NE and exclusively avoided pharmacological treatment.Keywords:Children, enuresis nocturna, pediatric urology, physicians, survey
  • PublicationOpen Access
    Radiation exposure during different percutaneous renal puncture techniques: A YAU endourology & urolithiasis study
    (2023-09-01) ŞENER, TARIK EMRE; TANIDIR, YILÖREN; KÜTÜKOĞLU, MEHMET UMUT; DÖRÜCÜ, DOĞANCAN; ŞENER T. E., TANIDIR Y., Ketenci S., Kutukoglu U., Dorucu D., Cayir H., Pietropaolo A., Emiliani E., Somani B.
    PURPOSE: Radiation exposure is affected by C-arm fluoroscopy device positioning during percutaneous renal puncture. Our aim was to compare the exposure of surgeon\"s lens, hand and chest with a fluoroscopy protocol replicated in different C-arm positions. MATERIALS AND METHODS: A standardized fluoroscopy protocol was created using water-equivalent solid phantoms to replicate a surgeon and patient. 111 mGy radiation (360 s) was applied in standard fluoroscopy mode (91 kVp, 2.7 mA/mAs). Dosimeters were placed on lens, chest and hand of surgeon and patient phantom models. 7 different C-arm positions were created: 0°, mediolateral (ML) +90°, ML -90°, ML +30°, ML -15°, craniocaudal (CC) +30°, CC +15°. Measurements were evaluated separately for different positions. RESULTS: The highest radiation exposure was measured on patient dosimeter (2.97 mSv). The highest exposure on surgeon was recorded on finger dosimeter in all C-arm positions; highest dose was recorded in ML +90° position (2.88 mSv). In finger dosimeters, lowest exposure was recorded in 0° position (0.51 mSv). The lowest exposure of all positions was measured in chest dosimeter in ML -90° position (0.24 mSv). CONCLUSIONS: In positions where X-ray generator of the C-arm was facing towards the surgeon, radiation exposure measured in all dosimeters was higher compared to positions where the generator was facing away. The hand radiation exposure in all positions was higher than chest and lens. Special care must be taken to avoid facing the X-ray generator tube and hands should be as well-protected as chest and eyes with special protective gear.