Person:
BAYRAM, FERİT

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

BAYRAM

First Name

FERİT

Name

Search Results

Now showing 1 - 7 of 7
  • PublicationOpen Access
    Effect of submucosal application of tramadol on postoperative pain after third molar surgery
    (BIOMED CENTRAL LTD, 2015-12) BAYRAM, FERİT; Gonul, Onur; Satilmis, Tulin; Bayram, Ferit; Gocmen, Gokhan; Sipahi, Aysegul; Goker, Kamil
    The aim of this study was to evaluate the effectiveness of submucosal application of tramadol, for acute postoperative facial pain, following the extraction of impacted third molar teeth. This prospective, double-blind, randomised placebo-controlled study included 60 ASA I-II patients undergoing impacted third molar surgery under local anaesthesia. Following the surgical procedure, patients were randomly divided into two groups; group T (1 mg/kg tramadol) and group S (2-mL saline). Treatments were applied submucosally after surgery. Pain after extraction was evaluated using a visual analogue scale (VAS) 0.5, 1, 2, 4, 6, 12, 24, and 48 h postoperatively. The time at which the first analgesic drug was taken, the total analgesic dose used, and adverse tissue reactions were also evaluated. In group T, postoperative VAS scores were significantly lower compared to that in group S (p < 0.05). This study demonstrated that post-operative submucosal application of tramadol is an effective method for reducing acute post-operative facial pain after impacted third molar surgery.
  • Publication
    A simple technique to facilitate the recording of intraoral scan data on cone-beam computed tomographic images during three-dimensional planning
    (CHURCHILL LIVINGSTONE, 2020) BAYRAM, FERİT; Gocmen, G. Bilgin; Bayram, F.; Aslan, Y. U.; Gocmen, G.
  • Publication
    The importance of maxillary sinuses in oral and maxillofacial surgical procedures
    (IntechOpen, 2023-12-01) GÖÇMEN, GÖKHAN; BAYRAM, FERİT; ATEŞ, OZAN; Göçmen G., Bayram F., Ateş O.
  • Publication
    Ensuring Function and Aesthetics with Orthognathic Surgery and Dental Implant in Patients with Skeletal Deformity: Case Series
    (2023-05-12) BAYRAM, FERİT; ŞANIVAR ABBASGHOLIZADEH, ZELİHA; ASLAN, YILMAZ UMUT; GÖÇMEN, GÖKHAN; EVREN, BUKET; ÖZKAN, YAŞAR; Kırıştıoğlu Z. B., Bayram F., Şanıvar Abbasgholızadeh Z., Aslan Y. U., Göçmen G., Evren B., Özkan Y.
  • Publication
    Technical note Arthrocentesis of temporomandibular joint with a tragus-supported guide: a technical note
    (CHURCHILL LIVINGSTONE, 2020) BAYRAM, FERİT; Gocmen, G.; Bayram, F.; Ozkan, Y.
  • Publication
    Influence of a Biodegradable Synthetic Hydrogel Used as a Guided Bone Regeneration Membrane in Sinus Floor Augmentation
    (MARMARA UNIV, INST HEALTH SCIENCES, 2018) BAYRAM, FERİT; Bayram, Ferit; Gocmen, Gokhan; Ozkan, Yasar
    Objective: The purpose of this study is to compare the clinical, histological, and radiological aspects of the polyethylene glycol (PEG) hydrogel membrane and the standard collagen membrane in sinus floor augmentation procedures when the same bone filling material is used. Methods: Fourteen patients (5 men and 9 women) were included in this prospective cohort study. Twenty sinus floor augmentation surgeries were randomly divided into two groups: the study group (n=10) and the control group (n=10). An anorganic bovine graft (Bio-Oss (R), Geistlich Pharma AG, Switzerland) was used in all patients as the bone-filling material. As a protective membrane, a collagen membrane (Bio-Gide (R), Geistlich Pharma AG, Switzerland) was used in the control group patients, as well as a PEG membrane (Membragel (R), Institut Straumann AG, Switzerland) in the study group. After 6 months, the samples were collected during implant site preparation for histopathological evaluation. Results: There were no statistically significant differences between the control and the study groups in the histological examination regarding the soft-to-hard tissue ratio. There was no statistically significant difference between the control and study groups in the resonance frequency analysis measurements at different times. No postoperative inflammation or exposure of the membrane was observed in any of the patients. The visual analogue scale scores measured at different times also showed no significant difference. Conclusion: A PEG membrane can be used as an alternative to a collagen membrane as a barrier in sinus floor augmentation procedures.
  • PublicationOpen Access
    Evaluation of Water Displacement Method in Estimating Mandibular Ramus Autograft Volume
    (2024-08-01) BAYRAM, FERİT; AŞKIN EKİNCİ, SENEM; GÖÇMEN, GÖKHAN; Bayram F., Aşkın Ekinci S., Göçmen G.
    Objective: This study aims to identify the most reliable method for measuring graft volumes comparable to those harvested from the ramus region using 3D-printed models. Methods: Using a cross-sectional design in an in vitro setting, CBCT images from 20 individuals who met the inclusion criteria for ramus grafting were examined. Volumetric evaluations were conducted on these images, and 3D-printed graft models were created. Two blinded raters assessed the graft volumes using the displacement method (with beakers of 10 cc, 25 cc, 50 cc capacity and a 100 cc biopsy cup) and the overflow liquid method (with beakers of 10 cc, 25 cc, and 50 cc capacity). The intraclass correlation coefficient and t tests were applied for statistical validation of intra- and inter-rater reliability. Results: High levels of both intra- and interrater reliability were observed, particularly for the 10 cc rise and overflow methods. These methods exhibited not only exceptionally high ICC values but also statistically meaningful p values. Furthermore, most of these methods strongly correlated and agreed with the CBCT measurements, except for the 50 cc overflow method, which showed significant divergence. Conclusion: The findings of this study validate the 10 cc beaker methods for reliable 3D printed ramus graft volume measurement and recommend a narrow-diameter syringe for optimal accuracy. These findings have crucial implications for both clinical practice and future research. Keywords: alveolar ride augmentation, three-dimensional image, organ size