Theoretical analysis of a cascade refrigeration system with natural and synthetic working fluid pairs for ultra low temperature applications

dc.contributor.authorsYilmaz B., Mançuhan E., Yilmaz D.
dc.date.accessioned2022-03-28T15:10:36Z
dc.date.accessioned2026-01-11T16:19:53Z
dc.date.available2022-03-28T15:10:36Z
dc.date.issued2020
dc.description.abstractIn this study, a theoretical model is established using Engineering Equation Solver (EES) software in order to investigate the effects of different design and operation parameters on the performance of the cascade systems for Ultra Low Temperature (ULT) between -50 oC and -100 oC. The analysis is performed for natural and synthetic refrigerant pairs to find an environmentally friendly alternative to commercial synthetic refrigerants. Effects of common parameters such as the evaporation temperature of low temperature cycle (LTC), the condensation temperature of high temperature cycle (HTC) and the temperature difference in the cascade heat exchanger (HX) have been investigated with the proposed model. Furthermore, influence of operation parameters including vapor quality of the refrigerant after the expansion valve and the precooler heat exchanger (PCHX) capacity, crucial to reach ULT conditions, on the system performance are examined. This study also contributes to the theoretical evaluation of the feasible natural refrigerant alternatives for ULT applications and the comparison of these refrigerants with synthetic ones in terms of performance and the environmental aspects. It is found that the natural refrigerant R1270/R170 pair results in about 5% better COP and almost half less CO2 emissions compared to synthetic refrigerant R404A/R508B pair. © 2020 Turk Isı Bilimi ve Teknigi Dernegi. All rights reserved.
dc.identifier.issn13003615
dc.identifier.urihttps://hdl.handle.net/11424/257399
dc.language.isoeng
dc.publisherTurk Isı Bilimi ve Teknigi Dernegi
dc.relation.ispartofIsi Bilimi Ve Teknigi Dergisi/ Journal of Thermal Science and Technology
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCascade Refrigeration System
dc.subjectCOP
dc.subjectNatural Refrigerants
dc.subjectTEWI
dc.subjectUltra-Low Temperature
dc.titleTheoretical analysis of a cascade refrigeration system with natural and synthetic working fluid pairs for ultra low temperature applications
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage153
oaire.citation.issue1
oaire.citation.startPage141
oaire.citation.titleIsi Bilimi Ve Teknigi Dergisi/ Journal of Thermal Science and Technology
oaire.citation.volume40

Files