Publication:
GSM based cathodic protection SCADA system [GSM tabanli katodi̇k koruma SCADA si̇stemi̇]

dc.contributor.authorsOnat M., Çetin M.S.
dc.date.accessioned2022-03-28T14:55:02Z
dc.date.accessioned2026-01-11T07:24:57Z
dc.date.available2022-03-28T14:55:02Z
dc.date.issued2008
dc.description.abstractMonitoring cathodic protections of steel and pre-stressed concrete cylinder pipes used in water supplies is realized by a GSM and microprocessor based SCADA system. Instead of using manual methods, automatically measuring the cathodic protection parameters such as system potential, pipe ground potential and anode current over GSM network are successfully achieved. All the relevant data are stored in a database and reported when needed. The whole water supply system is monitored in real-time via GSM. By applying the cathodic protection criteria for steel and pre-stressed concrete cylinder pipes, each measurement point is remotely determined through a control algorithm to check whether the cathodic protection is at satisfactory level.
dc.identifier.issn13001884
dc.identifier.urihttps://hdl.handle.net/11424/256206
dc.language.isotur
dc.relation.ispartofJournal of the Faculty of Engineering and Architecture of Gazi University
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAnode current
dc.subjectCathodic protection
dc.subjectGSM/SMS
dc.subjectPipe ground potential
dc.subjectSCADA
dc.subjectSystem potential
dc.titleGSM based cathodic protection SCADA system [GSM tabanli katodi̇k koruma SCADA si̇stemi̇]
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage594
oaire.citation.issue3
oaire.citation.startPage585
oaire.citation.titleJournal of the Faculty of Engineering and Architecture of Gazi University
oaire.citation.volume23