Publication: A useful method for the practice of pneumatic retinopexy: Slit-lamp laser photocoagulation through the gas bubble
| dc.contributor.author | SEVİK, MEHMET ORKUN | |
| dc.contributor.author | KUBAT, BETÜL | |
| dc.contributor.author | DERİCİOĞLU, VOLKAN | |
| dc.contributor.author | ŞAHİN, ÖZLEM | |
| dc.contributor.authors | Aykut A., SEVİK M. O., KUBAT B., DERİCİOĞLU V., ŞAHİN Ö. | |
| dc.date.accessioned | 2023-08-21T10:33:00Z | |
| dc.date.accessioned | 2026-01-10T18:32:35Z | |
| dc.date.available | 2023-08-21T10:33:00Z | |
| dc.date.issued | 2023-05-01 | |
| dc.description.abstract | This study aimed to demonstrate the laser retinopexy method through the gas bubble under a slit-lamp biomicroscope using a wide-field contact lens to treat rhegmatogenous retinal detachment (RRD) with pneumatic retinopexy (PR) and report its anatomical and functional results. This single-center, retrospective case series included RRD patients treated with PR using sulfur hexafluoride (SF6). The demographics, preoperative factors, and anatomical and functional outcomes were collected from the patient files. The single-procedure success rate of PR at postoperative 6th months was 70.8% (17/24 eyes), and the final success rate after secondary surgeries was 100%. The BCVA was better in the successful PR eyes at postoperative 3rd (p = 0.011) and 6th month (p = 0.016) than in failed eyes. No single preoperative factor was associated with PR success. The single-procedure success rate of PR using the laser retinopexy method through the gas bubble with a wide-field contact lens system seems comparable to the PR literature. | |
| dc.identifier.citation | Aykut A., SEVİK M. O., KUBAT B., DERİCİOĞLU V., ŞAHİN Ö., "A Useful Method for the Practice of Pneumatic Retinopexy: Slit-Lamp Laser Photocoagulation through the Gas Bubble", Journal of Personalized Medicine, cilt.13, sa.5, 2023 | |
| dc.identifier.doi | 10.3390/jpm13050741 | |
| dc.identifier.issn | 2075-4426 | |
| dc.identifier.issue | 5 | |
| dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85160310852&origin=inward | |
| dc.identifier.uri | https://hdl.handle.net/11424/292732 | |
| dc.identifier.volume | 13 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Journal of Personalized Medicine | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Tıp | |
| dc.subject | Sağlık Bilimleri | |
| dc.subject | Temel Tıp Bilimleri | |
| dc.subject | Medicine | |
| dc.subject | Health Sciences | |
| dc.subject | Fundamental Medical Sciences | |
| dc.subject | Klinik Tıp (MED) | |
| dc.subject | Klinik Tıp | |
| dc.subject | TIP, GENEL & DAHİLİ | |
| dc.subject | Clinical Medicine (MED) | |
| dc.subject | CLINICAL MEDICINE | |
| dc.subject | MEDICINE, GENERAL & INTERNAL | |
| dc.subject | Tıp (çeşitli) | |
| dc.subject | Medicine (miscellaneous) | |
| dc.subject | laser retinopexy | |
| dc.subject | pneumatic retinopexy | |
| dc.subject | retinal detachment | |
| dc.subject | sulfur hexafluoride | |
| dc.subject | wide-field contact lens | |
| dc.title | A useful method for the practice of pneumatic retinopexy: Slit-lamp laser photocoagulation through the gas bubble | |
| dc.type | article | |
| dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
