Publication:
A useful method for the practice of pneumatic retinopexy: Slit-lamp laser photocoagulation through the gas bubble

dc.contributor.authorSEVİK, MEHMET ORKUN
dc.contributor.authorKUBAT, BETÜL
dc.contributor.authorDERİCİOĞLU, VOLKAN
dc.contributor.authorŞAHİN, ÖZLEM
dc.contributor.authorsAykut A., SEVİK M. O., KUBAT B., DERİCİOĞLU V., ŞAHİN Ö.
dc.date.accessioned2023-08-21T10:33:00Z
dc.date.accessioned2026-01-10T18:32:35Z
dc.date.available2023-08-21T10:33:00Z
dc.date.issued2023-05-01
dc.description.abstractThis study aimed to demonstrate the laser retinopexy method through the gas bubble under a slit-lamp biomicroscope using a wide-field contact lens to treat rhegmatogenous retinal detachment (RRD) with pneumatic retinopexy (PR) and report its anatomical and functional results. This single-center, retrospective case series included RRD patients treated with PR using sulfur hexafluoride (SF6). The demographics, preoperative factors, and anatomical and functional outcomes were collected from the patient files. The single-procedure success rate of PR at postoperative 6th months was 70.8% (17/24 eyes), and the final success rate after secondary surgeries was 100%. The BCVA was better in the successful PR eyes at postoperative 3rd (p = 0.011) and 6th month (p = 0.016) than in failed eyes. No single preoperative factor was associated with PR success. The single-procedure success rate of PR using the laser retinopexy method through the gas bubble with a wide-field contact lens system seems comparable to the PR literature.
dc.identifier.citationAykut A., SEVİK M. O., KUBAT B., DERİCİOĞLU V., ŞAHİN Ö., "A Useful Method for the Practice of Pneumatic Retinopexy: Slit-Lamp Laser Photocoagulation through the Gas Bubble", Journal of Personalized Medicine, cilt.13, sa.5, 2023
dc.identifier.doi10.3390/jpm13050741
dc.identifier.issn2075-4426
dc.identifier.issue5
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85160310852&origin=inward
dc.identifier.urihttps://hdl.handle.net/11424/292732
dc.identifier.volume13
dc.language.isoeng
dc.relation.ispartofJournal of Personalized Medicine
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTıp
dc.subjectSağlık Bilimleri
dc.subjectTemel Tıp Bilimleri
dc.subjectMedicine
dc.subjectHealth Sciences
dc.subjectFundamental Medical Sciences
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectTIP, GENEL & DAHİLİ
dc.subjectClinical Medicine (MED)
dc.subjectCLINICAL MEDICINE
dc.subjectMEDICINE, GENERAL & INTERNAL
dc.subjectTıp (çeşitli)
dc.subjectMedicine (miscellaneous)
dc.subjectlaser retinopexy
dc.subjectpneumatic retinopexy
dc.subjectretinal detachment
dc.subjectsulfur hexafluoride
dc.subjectwide-field contact lens
dc.titleA useful method for the practice of pneumatic retinopexy: Slit-lamp laser photocoagulation through the gas bubble
dc.typearticle
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
543.64 KB
Format:
Adobe Portable Document Format