Publication:
The influence of bond-coating on plasma sprayed alumina-titania, doped with biologically derived hydroxyapatite, on stainless steel

Loading...
Thumbnail Image

Date

Authors

Journal Title

Journal ISSN

Volume Title

Publisher

TAYLOR & FRANCIS LTD

Research Projects

Organizational Units

Journal Issue

Abstract

The influence of bond-coating on the quality of thin coatings (similar to 100 mu m) of alumina-titania (60%-40%), doped with 5% and 10% bovine hydroxyapatite, plasma-spayed on stainless steel (316), was experimentally investigated by measuring the tensile strength and the ratio of adhesive/cohesive strength of the coatings. The bond-coating layer was alumina-titania (60%-40%). The experimental results (mainly the values of the ratio adhesive/cohesive strength and the microstructure of the coating layers) and their discussion in the light of earlier similar studies show that bond-coating process can result in coating composite structures of high quality, which is of high importance for devices used in biomedicine.

Description

Citation

Endorsement

Review

Supplemented By

Referenced By