Publication:
A comparison of four different microleakage tests for assessment of leakage of root canal fillings

dc.contributor.authorGENÇOĞLU, NİMET
dc.contributor.authorsKaragenc, Beril; Gencoglu, Nimet; Ersoy, Mustafa; Cansever, Galip; Kulekci, Guven
dc.date.accessioned2022-03-12T15:59:37Z
dc.date.accessioned2026-01-10T21:00:25Z
dc.date.available2022-03-12T15:59:37Z
dc.date.issued2006
dc.description.abstractObjective. The purpose of this study was to compare four different microleakage tests (dye leakage, electrochemical test, bacterial test and fluid filtration) for evaluation of the coronal seal of teeth obturated using Thermafil or lateral condensation techniques. Study design. One hundred forty-four extracted single-rooted teeth were selected and prepared. The specimens were divided into 8 experimental groups. In 4 groups the root canals were filled with Thermafil obturators and in the other 4 groups by the lateral condensation technique. Coronal microleakage was assessed after exposing one group of specimens (n = 15 teeth) from each of the obturation techniques to each of the four microleakage tests. Results. In the fluid filtration test, lateral condensation showed statistically less leakage than the Thermafil technique (P <.05). Electrochemical and dye leakage test results showed no difference between the two obturation techniques (P <.05). However, in the bacterial leakage test, Thermafil showed less leakage than lateral condensation (P <.05). Conclusion. There is poor correlation between various methods to evaluate hydraulic leakage. The clinical significance of leakage tests in vitro is questionable.
dc.identifier.doi10.1016/j.tripleo.2005.10.044
dc.identifier.issn1079-2104
dc.identifier.pubmed16831682
dc.identifier.urihttps://hdl.handle.net/11424/224462
dc.identifier.wosWOS:000239158800019
dc.language.isoeng
dc.publisherMOSBY, INC
dc.relation.ispartofORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDYE-PENETRATION
dc.subjectFLUID TRANSPORT
dc.subjectRELIABILITY
dc.subjectTHERMAFIL
dc.subjectSEALER
dc.subjectMODEL
dc.titleA comparison of four different microleakage tests for assessment of leakage of root canal fillings
dc.typeconferenceObject
dspace.entity.typePublication
oaire.citation.endPage113
oaire.citation.issue1
oaire.citation.startPage110
oaire.citation.titleORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS
oaire.citation.volume102

Files