Publication: Reliability of quantitative ultrasound measurement of flexor digitorum superficialis and profundus muscles in stroke
| dc.contributor.author | YAĞCI, İLKER | |
| dc.contributor.author | KENİŞ COŞKUN, ÖZGE | |
| dc.contributor.authors | Kenis-Coskun, Ozge; Giray, Esra; Gencer-Atalay, Zeynep Kardelen; Yagci, Ilker; Karadag-Saygi, Evrim | |
| dc.date.accessioned | 2022-03-12T22:40:35Z | |
| dc.date.accessioned | 2026-01-11T09:39:00Z | |
| dc.date.available | 2022-03-12T22:40:35Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | Aim: This study aims to investigate reliability of quantitative ultrasound measurement of the flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) muscles in stroke. Materials & methods: Patients with a history of stroke were recruited. FDP and FDS muscles on both upper extremities were investigated with ultrasound. Two independent assessors acquired images and analyzed them using a program and Heckmatt scale. Results: Forty-eight patients were included. The inter-rater intraclass correlation coefficient for echo intensities was calculated as 0.91 while intrarater intraclass correlation coefficient as 0.80. For Heckmatt scale, the inter-rater reliability for FDS was Kw = 0.74 (p < 0.0005) and for FDP it was Kw = 0.73 (p < 0.0005). Mean echo intensity values showed significant strong correlations with Heckmatt scores (r = 0.663 and r = 0.633 with both p values <0.001). Conclusion: Quantitative ultrasound imaging of FDS and FDP is a reliable method to demonstrate echo intensity changes of muscles in stroke. | |
| dc.identifier.doi | 10.2217/cer-2020-0105 | |
| dc.identifier.eissn | 2042-6313 | |
| dc.identifier.issn | 2042-6305 | |
| dc.identifier.pubmed | 33325276 | |
| dc.identifier.uri | https://hdl.handle.net/11424/235986 | |
| dc.identifier.wos | WOS:000599189800001 | |
| dc.language.iso | eng | |
| dc.publisher | FUTURE MEDICINE LTD | |
| dc.relation.ispartof | JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | quantitative analysis | |
| dc.subject | reliability | |
| dc.subject | spasticity | |
| dc.subject | stroke | |
| dc.subject | ultrasound | |
| dc.subject | INTERRATER RELIABILITY | |
| dc.subject | ASHWORTH SCALE | |
| dc.subject | INTEROBSERVER | |
| dc.subject | ANGLE | |
| dc.title | Reliability of quantitative ultrasound measurement of flexor digitorum superficialis and profundus muscles in stroke | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 1300 | |
| oaire.citation.issue | 18 | |
| oaire.citation.startPage | 1293 | |
| oaire.citation.title | JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH | |
| oaire.citation.volume | 9 |
