Publication:
A novel method to assess intraarticular screw penetration into the joint space

dc.contributor.authorKÜÇÜKDURMAZ, FATİH
dc.contributor.authorsCeylan, Hasan Huseyin; Erden, Tunay; Kapicioglu, Mehmet; Kucukdurmaz, Fatih
dc.date.accessioned2022-04-25T00:11:48Z
dc.date.accessioned2026-01-11T19:03:11Z
dc.date.available2022-04-25T00:11:48Z
dc.date.issued2020
dc.description.abstractObjectives: This study aims to propose a novel method to detect articular penetration of screws by relying on their electrical conductivity properties and control the validity of this method. Materials and methods: In this ex vivo study, conducted between June 2017 and August 2017, we used five fresh sheep shoulder joints. First, the shoulder joint space was filled with saline solution. An insulated cannula was placed in the joint capsule, and a conductive wire was introduced into the joint via this cannula. A single titanium screw was inserted from the tuberculum majus into the posteroinferior quadrant of the humeral head under fluoroscopic observation. Conductivity was continuously measured using a digital multimeter. When a sudden decrease in conduction resistance was detected, fluoroscopic images were obtained in the anteroposterior (AP) and lateral directions. These images were assessed for penetration by a blinded surgeon. Penetration was confirmed by dissection of the joint. Results: There was a significant decrease in electrical resistance when screw penetration occurred (p<0.001). All penetration events were confirmed using our novel method. For all five of the specimens, either AP or lateral images could not be used to confirm penetration. For two of these specimens, penetration was undetectable in both AP and lateral fluoroscopic images, but a decrease in resistance was recorded. Conclusion: The described method exhibits greater sensitivity and accuracy for metal penetration to joint, and it is effective in detecting screws in the joints. The novel method described in this paper was applied in a prototype setting, and we believe that this concept can continue to be developed.
dc.identifier.doi10.5606/ehc.2020.71764
dc.identifier.eissn2687-4792
dc.identifier.issn2687-4784
dc.identifier.pubmed32584717
dc.identifier.urihttps://hdl.handle.net/11424/263971
dc.identifier.wosWOS:000545984600008
dc.languageeng
dc.publisherTURKISH JOINT DISEASES FOUNDATION
dc.relation.ispartofJOINT DISEASES AND RELATED SURGERY
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectComplication
dc.subjectfluoroscopy
dc.subjectscrew penetration
dc.subjecttrauma
dc.subjectLOCKING PLATE OSTEOSYNTHESIS
dc.subjectPROXIMAL HUMERAL FRACTURES
dc.subjectINTERNAL-FIXATION
dc.subjectOPEN REDUCTION
dc.subjectLOCKED PLATE
dc.subjectCOMPLICATIONS
dc.subjectMULTICENTER
dc.titleA novel method to assess intraarticular screw penetration into the joint space
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage222
oaire.citation.issue2
oaire.citation.startPage218
oaire.citation.titleJOINT DISEASES AND RELATED SURGERY
oaire.citation.volume31

Files