Publication:
Assessment of average of normals (AON) procedure for outlier-free datasets including qualitative values below limit of detection (LoD): an application within tumor markers such as CA 15-3, CA 125, and CA 19-9

dc.contributor.authorÇİLİNGİRTÜRK, AHMET METE
dc.contributor.authorsUsta, Murat; Aral, Hale; Mete Cilingirturk, Ahmet; Kural, Alev; Topac, Ibrahim; Semerci, Tuna; Koseoglu, Mehmet Hicri
dc.date.accessioned2022-03-12T20:29:57Z
dc.date.accessioned2026-01-11T10:35:29Z
dc.date.available2022-03-12T20:29:57Z
dc.date.issued2016
dc.description.abstractAverage of normals (AON) is a quality control procedure that is sensitive only to systematic errors that can occur in an analytical process in which patient test results are used. The aim of this study was to develop an alternative model in order to apply the AON quality control procedure to datasets that include qualitative values below limit of detection (LoD). The reported patient test results for tumor markers, such as CA 15-3, CA 125, and CA 19-9, analyzed by two instruments, were retrieved from the information system over a period of 5 months, using the calibrator and control materials with the same lot numbers. The median as a measure of central tendency and the median absolute deviation (MAD) as a measure of dispersion were used for the complementary model of AON quality control procedure. The u(bias) values, which were determined for the bias component of the measurement uncertainty, were partially linked to the percentages of the daily median values of the test results that fall within the control limits. The results for these tumor markers, in which lower limits of reference intervals are not medically important for clinical diagnosis and management, showed that the AON quality control procedure, using the MAD around the median, can be applied for datasets including qualitative values below LoD.
dc.identifier.doi10.1080/00365513.2016.1210225
dc.identifier.eissn1502-7686
dc.identifier.issn0036-5513
dc.identifier.pubmed27687786
dc.identifier.urihttps://hdl.handle.net/11424/234134
dc.identifier.wosWOS:000385808700004
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS LTD
dc.relation.ispartofSCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectData analysis
dc.subjectlimit of detection
dc.subjectqualitative evaluation
dc.subjectquality control
dc.subjecttumor markers
dc.subjectBIOLOGICAL VARIATION
dc.subjectANALYTICAL PERFORMANCE
dc.subjectMONITORING PATIENTS
dc.subjectOVARIAN-CANCER
dc.subjectBREAST-CANCER
dc.subjectPATIENT DATA
dc.subjectANTIGEN
dc.subjectSERUM
dc.subjectASSAY
dc.subjectINDIVIDUALS
dc.titleAssessment of average of normals (AON) procedure for outlier-free datasets including qualitative values below limit of detection (LoD): an application within tumor markers such as CA 15-3, CA 125, and CA 19-9
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage560
oaire.citation.issue7
oaire.citation.startPage553
oaire.citation.titleSCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION
oaire.citation.volume76

Files