Publication:
Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM

dc.contributor.authorGENÇOĞLU, NİMET
dc.contributor.authorsKaratekin, Anil Ozgun; Keles, Ali; Gencoglu, Nimet
dc.date.accessioned2022-03-14T09:16:40Z
dc.date.accessioned2026-01-10T18:34:37Z
dc.date.available2022-03-14T09:16:40Z
dc.date.issued2019-11-21
dc.description.abstractAim To compare the efficiency of continuous wave obturation and cold lateral condensation techniques and filling time in C-shape canals of 3-dimensional (3D)-printed resin teeth shaped with Reciproc Blue (VDW) or Hyflex EDM (Coltene/Whaledent). Methodology One tooth with C1-type orifice and root canal morphology and one with C2-type orifice and C2-C3 root canal morphology were selected based on CBCT. Two replicas of selected teeth were manufactured with a 3D-printer and their canals were instrumented with Reciproc Blue or Hyflex EDM. These 4 instrumented replicas were scanned with CBCT. Identical 10 replicas of each group (total of 40) were produced using a 3D-printer and randomly divided into 2 groups (n = 5), root filled with either continuous wave obturation (CW) or cold lateral condensation (LC). Horizontal cross-sections of C1-type were made at 2, 4, 6, 8 mm and C2-type at 2, 4, 6 mm from the apical foramen. Gutta-percha, sealer and void areas were evaluated with image analysis sofware. Data were analysed using nonparametric Kruskal-Wallis and Mann Whitney-U tests and the Factorial ANOVA was used for interaction effects. Time required to fill canals was evaluated using the Mann-Whitney U test. Results For C1-type, LC had more gutta-percha and less sealer compared to CW in 2-mm sections (p<0.05). CW had greater percentages of gutta-percha and lower percentages of sealer compared with LC group in 4, 6, 8 mm sections and total area (p<0.05). LC group had higher percentages of voids compared to CW group in 2 and 4 mm sections (p<0.05). For C2-type, CW had more gutta-percha and less sealer versus LC group in all sections and total area (p<0.05). LC had the least gutta-percha and greatest sealer percentages at 6-mm sections (p<0.05). There was no statistically significant difference in the percentages of voids at any level of sections between the filling techniques (p>0.05). In both C-types, there was no significant difference in the percentages of gutta-percha, sealer and voids between Reciproc Blue and Hyflex EDM-shaped groups at any level (p>0.05). Time spent for the LC technique and filling C1-type was significantly longer than when using the CW technique and filling C2-type (p<0.05). Conclusions Continuous wave obturation was more effective than lateral condensation in both C1- and C2-type, except for the apical 2 mm section of C1-type, suggesting the need for a modified CW technique.
dc.identifier.doi10.1371/journal.pone.0224793
dc.identifier.issn1932-6203
dc.identifier.pubmed31751375
dc.identifier.urihttps://hdl.handle.net/11424/242893
dc.identifier.wosWOS:000533886900019
dc.language.isoeng
dc.publisherPUBLIC LIBRARY SCIENCE
dc.relation.ispartofPLOS ONE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMANDIBULAR 2ND MOLARS
dc.subjectROOT CANALS
dc.subjectPART II
dc.subject1ST MOLAR
dc.subjectSYSTEM
dc.subjectCONFIGURATION
dc.subjectPOPULATION
dc.subjectOBTURATIONS
dc.subject2ND-MOLARS
dc.subjectMICROSEAL
dc.titleComparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM
dc.typearticle
dspace.entity.typePublication
oaire.citation.issue11
oaire.citation.titlePLOS ONE
oaire.citation.volume14

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
4.01 MB
Format:
Adobe Portable Document Format