Publication: Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM
| dc.contributor.author | GENÇOĞLU, NİMET | |
| dc.contributor.authors | Karatekin, Anil Ozgun; Keles, Ali; Gencoglu, Nimet | |
| dc.date.accessioned | 2022-03-14T09:16:40Z | |
| dc.date.accessioned | 2026-01-10T18:34:37Z | |
| dc.date.available | 2022-03-14T09:16:40Z | |
| dc.date.issued | 2019-11-21 | |
| dc.description.abstract | Aim To compare the efficiency of continuous wave obturation and cold lateral condensation techniques and filling time in C-shape canals of 3-dimensional (3D)-printed resin teeth shaped with Reciproc Blue (VDW) or Hyflex EDM (Coltene/Whaledent). Methodology One tooth with C1-type orifice and root canal morphology and one with C2-type orifice and C2-C3 root canal morphology were selected based on CBCT. Two replicas of selected teeth were manufactured with a 3D-printer and their canals were instrumented with Reciproc Blue or Hyflex EDM. These 4 instrumented replicas were scanned with CBCT. Identical 10 replicas of each group (total of 40) were produced using a 3D-printer and randomly divided into 2 groups (n = 5), root filled with either continuous wave obturation (CW) or cold lateral condensation (LC). Horizontal cross-sections of C1-type were made at 2, 4, 6, 8 mm and C2-type at 2, 4, 6 mm from the apical foramen. Gutta-percha, sealer and void areas were evaluated with image analysis sofware. Data were analysed using nonparametric Kruskal-Wallis and Mann Whitney-U tests and the Factorial ANOVA was used for interaction effects. Time required to fill canals was evaluated using the Mann-Whitney U test. Results For C1-type, LC had more gutta-percha and less sealer compared to CW in 2-mm sections (p<0.05). CW had greater percentages of gutta-percha and lower percentages of sealer compared with LC group in 4, 6, 8 mm sections and total area (p<0.05). LC group had higher percentages of voids compared to CW group in 2 and 4 mm sections (p<0.05). For C2-type, CW had more gutta-percha and less sealer versus LC group in all sections and total area (p<0.05). LC had the least gutta-percha and greatest sealer percentages at 6-mm sections (p<0.05). There was no statistically significant difference in the percentages of voids at any level of sections between the filling techniques (p>0.05). In both C-types, there was no significant difference in the percentages of gutta-percha, sealer and voids between Reciproc Blue and Hyflex EDM-shaped groups at any level (p>0.05). Time spent for the LC technique and filling C1-type was significantly longer than when using the CW technique and filling C2-type (p<0.05). Conclusions Continuous wave obturation was more effective than lateral condensation in both C1- and C2-type, except for the apical 2 mm section of C1-type, suggesting the need for a modified CW technique. | |
| dc.identifier.doi | 10.1371/journal.pone.0224793 | |
| dc.identifier.issn | 1932-6203 | |
| dc.identifier.pubmed | 31751375 | |
| dc.identifier.uri | https://hdl.handle.net/11424/242893 | |
| dc.identifier.wos | WOS:000533886900019 | |
| dc.language.iso | eng | |
| dc.publisher | PUBLIC LIBRARY SCIENCE | |
| dc.relation.ispartof | PLOS ONE | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | MANDIBULAR 2ND MOLARS | |
| dc.subject | ROOT CANALS | |
| dc.subject | PART II | |
| dc.subject | 1ST MOLAR | |
| dc.subject | SYSTEM | |
| dc.subject | CONFIGURATION | |
| dc.subject | POPULATION | |
| dc.subject | OBTURATIONS | |
| dc.subject | 2ND-MOLARS | |
| dc.subject | MICROSEAL | |
| dc.title | Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.issue | 11 | |
| oaire.citation.title | PLOS ONE | |
| oaire.citation.volume | 14 |
Files
Original bundle
1 - 1 of 1
