dc.description.abstractObjective:The aim was to compare the shaping ability and the canal straightening of T-Endo MUST and WaveOne Gold reciprocal file systems with glide path files in resin J-shaped root canals.Material and Methods:Two groups (n=17) were established. TEM tg (13/.04) + TEM M25 (25/.06) and WOG Glider (15/.02) + WOG Primary (25/.07) were used to prepare the resin simulated canals. A series of preoperative and postoperative images were taken by a digital camera and they were superimposed. The curvature angles and the amount of resin removed from both the inner and the outer wall of the canal into the level of 7 mm from the apical point, with a 1 mm increment were measured. The data were evaluated with independent samples Student’s t-test with 5% significance interval.Results:There was no statistically difference between TEM and WOG reciprocal files (p>0.05). No instrument fracture or canal aberrations were inspected during canal preparation.Conclusion:Within the limitation of this present study, TEM and WOG files maintained the original canal curvature in curved canals. They produced conservative shapes with lower foramen transportation.
dc.description.abstractT-Endo MUST ve WaveOne Gold resiprokal eğe sistemlerinin rehber yol eğeleri ile birlikte rezin J-şekilli kanallardaki şekillendirme kabiliyetini ve kanal düzleştirmesini karşılaştırmaktır. Gereç ve Yöntemler: İki grup (n=17) oluşturuldu. Rezin kanalları genişletmek için TEM tg (13/.04) + TEM M25 (25/.06) ve WOG Glider (15/.02) + WOG Primary (25/.07) kullanıldı. İşlem öncesi ve sonrası görüntüler dijital kamera ile çekildi ve üst üste bindirildi. Eğrilik açıları ve kanalın hem iç hem de dış duvarından apikal noktadan 7 mm seviyesine kadar, uzaklaştırılan rezin miktarı 1 mm’lik aralıklarla ölçüldü. Bağımsız örneklem grubuna %5 anlamlılık seviyesine göre Student t-testi uygulanmıştır. Bulgular: TEM ve WOG resiprokal eğe sistemleri arasında istatistiksel olarak anlamlı bir fark bulunmamıştır (p>0,05). Kanal genişletilmesi sırasında alet kırığı görülmemiştir. Sonuç: Bu çalışmanın sınırlamaları dâhilinde TEM ve WOG, eğimli kanallarda orijinal kanal eğriliğini korumuştur. Daha düşük apikal transportasyon ile konservatif bir kanal genişletmesi gerçekleştirdiler.
dc.identifier.citationFalakaloğlu S., İriboz E., "Comparison of Shaping Ability of T-Endo MUST and WaveOne Gold with Glide Path Instruments: An In Vitro Study", Türkiye Klinikleri Diş Hekimliği Bilimleri Dergisi, cilt.28, sa.2, ss.390-395, 2022
dc.identifier.doi10.5336/dentalsci.2021-85047
dc.identifier.endpage395
dc.identifier.issn1300-7734
dc.identifier.issue2
dc.identifier.startpage390
dc.identifier.urihttps://avesis.marmara.edu.tr/api/publication/ad136a3f-2013-41ce-a647-c741736ff1a0/file
dc.identifier.urihttps://hdl.handle.net/11424/291030
dc.identifier.volume28
dc.language.isoeng
dc.relation.ispartofTürkiye Klinikleri Diş Hekimliği Bilimleri Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectSağlık Bilimleri
dc.subjectDiş Hekimliği
dc.subjectKlinik Bilimler
dc.subjectEndodonti
dc.subjectHealth Sciences
dc.subjectDentistry
dc.subjectClinical Sciences
dc.subjectEndodontics
dc.subjectKlinik Tıp (MED)
dc.subjectKlinik Tıp
dc.subjectDİŞ HEKİMLİĞİ, ORAL CERRAHİ VE TIP
dc.subjectClinical Medicine (MED)
dc.subjectCLINICAL MEDICINE
dc.subjectDENTISTRY, ORAL SURGERY & MEDICINE
dc.subjectOrtodonti
dc.subjectAğız Cerrahisi
dc.subjectDiş Hekimliği (çeşitli)
dc.subjectDiş Hijyeni
dc.subjectPeriodontoloji
dc.subjectDişçilik Hizmetleri
dc.subjectOrthodontics
dc.subjectOral Surgery
dc.subjectDentistry (miscellaneous)
dc.subjectDental Hygiene
dc.subjectPeriodontics
dc.subjectDental Assisting
dc.subjectGeneral Dentistry
dc.subjectEndodonti
dc.subjectkök kanalı hazırlama
dc.subjectkök kanalı tedavisi
dc.subjectEndodontics
dc.subjectroot canal preparation
dc.subjectroot canal therapy
dc.titleComparison of shaping ability of t-endo must and waveone gold with glide path instruments: an in vitro study
dc.title.alternativeT-endo MUST ve waveOne gold’un rehber yol eğeleri ile şekillendirme yeteneklerinin karşılaştırılması: İn vitro çalışma
dc.typearticle
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
396.83 KB
Format:
Adobe Portable Document Format