Publication:
Bearing Fault Diagnosis in Electric Motors: the Example of Bahcesehir Natural Gas Electric Plant

dc.contributor.authorsYilmaz, Oe.; Akinci, T. C.; Kuseyri, S.
dc.date.accessioned2022-03-12T16:00:43Z
dc.date.accessioned2026-01-11T16:29:22Z
dc.date.available2022-03-12T16:00:43Z
dc.date.issued2009
dc.description.abstractIn this article, an experimental study based on the farsighted maintenance technology has been carried out on bearing fault development in asynchronous motors. The experimental studies have been carried out at a thermal power plant located in Istanbul-Esenyurt. The plant is a special-purpose company founded to implement the project of natural gas fired combined-cycle and cogeneration system having the capacity of 180 MW electricity and 180 MW heat. Esenyurt Power Plant has been developed to meet both the heat energy requirement of the region and electricity requirement of the country. The electric energy produced by the plant is transferred to the national network at 154 kV high-voltage line passing over the plant area. There are various induction motors in the power plant. Though the critical machines have stand-by units, any failures which may occur in the motors may cause workforce loss, time loss and economical losses. For that purpose, the bearing faults which may occur in the machines are detected at the start-Lip phase by making character inference of the vibration indications received from the motor regarding bearing faults; and by this way they can be replaced before they cause any failure in the machines.
dc.identifier.doidoiWOS:000266322100024
dc.identifier.issn1822-2951
dc.identifier.urihttps://hdl.handle.net/11424/224734
dc.identifier.wosWOS:000266322100024
dc.language.isoeng
dc.publisherKAUNAS UNIV TECHNOLOGY PRESS
dc.relation.ispartofMECHANIKA 2009 - PROCEEDINGS OF THE 14TH INTERNATIONAL CONFERENCE
dc.relation.ispartofseriesMechanika Kaunas University of Technology
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectbearing fault diagnosis
dc.subjectfault detection
dc.subjectpredictive maintenance
dc.titleBearing Fault Diagnosis in Electric Motors: the Example of Bahcesehir Natural Gas Electric Plant
dc.typeconferenceObject
dspace.entity.typePublication
oaire.citation.endPage136
oaire.citation.startPage133
oaire.citation.titleMECHANIKA 2009 - PROCEEDINGS OF THE 14TH INTERNATIONAL CONFERENCE