Publication:
Shear Wave Elastography in Placental Dysfunction Comparison of Elasticity Values in Normal and Preeclamptic Pregnancies in the Second Trimester

dc.contributor.authorsCimsit, Canan; Yoldemir, Tevfik; Akpinar, Ihsan Nuri
dc.date.accessioned2022-03-13T12:48:06Z
dc.date.accessioned2026-01-10T17:06:03Z
dc.date.available2022-03-13T12:48:06Z
dc.date.issued2015
dc.description.abstractObjectives The aim of this study was to determine whether shear wave elastography of the placenta differs between normal pregnancies and pregnancies complicated by preeclampsia between 20 and 23 weeks' gestation. Methods A prospective study was performed with 204 consecutive singleton pregnancies that had routine anomaly scanning between 20 and 23 weeks' gestation. One hundred twenty-nine of these patients were examined with shear wave elastography; 101 women who had clinically normal pregnancies with normal fetal biomenic measurements and normal deliveries without any perinatal complications formed group A, and 28 women who had a clinical diagnosis of early-onset preeclampsia before anomaly scanning formed group B. Women with either posterior placentations (n = 63) or other obstetric disorders (n = 12) were excluded from the study. Results Shear wave elastographic values for group B were significantly higher than those for group A (P <.05). No statistically significant difference was found between the elasticity values measured at the center or edge of the placenta (P>.05). Conclusions Shear wave elastography differentiates between the placental elasticity of normal pregnancies and pregnancies complicated by preeclampsia when performed during the second trimester. As a new method for tissue characterization, shear wave elastography is useful for evaluation of placental function and can be used as a supplement to existing methods for prediction of preeclampsia.
dc.identifier.doi10.7863/ultra.34.1.151
dc.identifier.eissn1550-9613
dc.identifier.issn0278-4297
dc.identifier.pubmed25542951
dc.identifier.urihttps://hdl.handle.net/11424/238164
dc.identifier.wosWOS:000347364800018
dc.language.isoeng
dc.publisherWILEY
dc.relation.ispartofJOURNAL OF ULTRASOUND IN MEDICINE
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectobstetric ultrasound
dc.subjectplacental dysfunction
dc.subjectplacental elasticity
dc.subjectpreeclampsia
dc.subjectshear wave elastography
dc.subjectsonoelastography
dc.subjectUTERINE ARTERY DOPPLER
dc.subjectREAL-TIME ELASTOGRAPHY
dc.subjectGESTATIONAL-AGE
dc.subjectPREDICTION
dc.subjectDIAGNOSIS
dc.subjectWOMEN
dc.titleShear Wave Elastography in Placental Dysfunction Comparison of Elasticity Values in Normal and Preeclamptic Pregnancies in the Second Trimester
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage159
oaire.citation.issue1
oaire.citation.startPage151
oaire.citation.titleJOURNAL OF ULTRASOUND IN MEDICINE
oaire.citation.volume34

Files