Publication:
Marginal adaptation of ceramic inserts after cementation

dc.contributor.authorsOzcan, M; Pfeiffer, P; Nergiz, I
dc.date.accessioned2022-03-12T16:59:43Z
dc.date.accessioned2026-01-11T10:34:38Z
dc.date.available2022-03-12T16:59:43Z
dc.date.issued2002
dc.description.abstractThe advantage of using ceramic inserts is to prevent major drawbacks of composite resins such as polymerization shrinkage, wear and microleakage. This in vitro study evaluated the marginal adaptation of two approximal ceramic insert systems after cementation to the cavities opened with ultrasonic tips. Proximal cavities with margins in enamel were prepared in 20 intact molars using ultrasonic tips (SONICSYS approx tips [microtorpedo size #2 and #3]; Siplus Instrument approximal [U-shaped]). Inserts of similar sizes (n=10) from two systems corresponding to the ultrasonic tips were placed in the cavities (SONICSYS Inlay; SDS-Inlay system), one on the mesial side and the other on the distal side of the same molar. Following cementation and thermocycling (5000 cycles, between 5-55degreesC), cement thickness was measured at the buccal, lingual walls and pulpal floors of the proximal boxes under light microscope (x150). The mean cement thickness values recorded for SONICSYS inserts #2 (25 mum) was not significantly different (p>0.05) from that of SDS inserts of similar size (26 mum). There was a significant difference (p<0.05) in cement thickness values between SONICSYS #3 inserts (34 &mu;m) and SDS inserts of similar size (23 &mu;m). Comparison of mean values between the ceramic insert systems examined revealed that marginal adaptation was better at the buccal and lingual proximal walls than those at the pulpal floor in the SDS system, however, there was no difference for SONICSYS at both sizes. Ceramic inserts placed in cavities prepared with ultrasonic tips provide clinically acceptable marginal quality.
dc.identifier.doidoiWOS:000174214400006
dc.identifier.issn0361-7734
dc.identifier.pubmed11931135
dc.identifier.urihttps://hdl.handle.net/11424/227231
dc.identifier.wosWOS:000174214400006
dc.language.isoeng
dc.publisherOPERATIVE DENTISTRY INC
dc.relation.ispartofOPERATIVE DENTISTRY
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCOMPOSITE RESTORATIONS
dc.subjectINLAY
dc.subjectREDUCTION
dc.titleMarginal adaptation of ceramic inserts after cementation
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage136
oaire.citation.issue2
oaire.citation.startPage132
oaire.citation.titleOPERATIVE DENTISTRY
oaire.citation.volume27

Files