Publication:
Development and validation of a RP-HPLC method for quality control of oxantel pamoate, pyrantel pamoat and praziquantel in tablets

dc.contributor.authorsTatar, Esra; Ates, Gokhan; Kucukguzel, Ilkay
dc.date.accessioned2022-03-13T12:47:10Z
dc.date.accessioned2026-01-10T17:06:20Z
dc.date.available2022-03-13T12:47:10Z
dc.date.issued2015
dc.description.abstractIn the present study, simple, rapid and precise HPLC methods were developed which would be useful for quality control of pharmaceutical dosage forms containing praziquantel (PRZ), pyrantel pamoate (PPA) and oxantel pamoate (OPA). The first method (M-1) was developed for the analysis of PRZ; separation was achieved using a reversed-phase column (4.6 x 150 mm, 5 mu m) C18, a mobile phase comprising ACN:MeOH:20 mM phosphate buffer (0.2 % TEA, pH 4.5) (50: 10: 40, v/v/v) and UV detection at 210 nm. PPA and OPA were analysed simultaneously using a separate method (M-2) by employing the same column and flow rate. In accordance with the second method (M-2), detection wavelength was set at 295 nm and a mobile phase of ACN: MeOH: 20 mM phosphate buffer (0.2 % TEA, pH 4.5) (12: 3: 85, v/v/v) was used. Benazepril hydrochloride (BZP) and paracetamol (PAR) were used as internal standards (IS) of the methods M-1 and M-2, respectively. Both methods were validated based on the parameters such as specifity, linearity, precision, accuracy, limit of detection (LOD) and limit of quantitation (LOQ) besides system suitability tests. Forced degradation studies were performed to indicate specifity of the proposed methods. The methods were found linear over the concentration ranges of 0.5-7.5 mu g/mL, 1-15 mu g/mL and 2-40 mu g/mL for PRZ, PPA and OPA, respectively. Correlation coefficients (r) of the regression equations were greater than 0.999 in all cases. The precision of the methods was demonstrated using intra-and inter-day assay RSD values which were less than 1% in all instances. Accuracy of the proposed methods was tested on placebo tablets spiked with known amounts of actives. Resulting recoveries of assays were in the range of 99.9-101.1 % whereas, those from commercial tablets were 99.4-100.8 %.
dc.identifier.doidoiWOS:000361222600004
dc.identifier.issn1309-0801
dc.identifier.urihttps://hdl.handle.net/11424/238036
dc.identifier.wosWOS:000361222600004
dc.language.isoeng
dc.publisherMARMARA UNIV, FAC MEDICINE
dc.relation.ispartofMARMARA PHARMACEUTICAL JOURNAL
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectOxantel pamoate
dc.subjectPyrantel pamoate
dc.subjectPraziquantel
dc.subjectHPLC
dc.subjectanalytical method validation
dc.subjectPERFORMANCE LIQUID-CHROMATOGRAPHY
dc.subjectMASS-SPECTROMETRY
dc.subjectCAPILLARY-ELECTROPHORESIS
dc.subjectPLASMA
dc.subjectFENBENDAZOLE
dc.subjectSPECTROSCOPY
dc.subjectALBENDAZOLE
dc.subjectMETABOLITES
dc.subjectMEBENDAZOLE
dc.subjectTARTRATE
dc.titleDevelopment and validation of a RP-HPLC method for quality control of oxantel pamoate, pyrantel pamoat and praziquantel in tablets
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage35
oaire.citation.issue1
oaire.citation.startPage27
oaire.citation.titleMARMARA PHARMACEUTICAL JOURNAL
oaire.citation.volume19

Files