Publication:
In Vitro Comparison of Marginal and Internal Fit of Press-on-Metal Ceramic (PoM) Restorations with Zirconium-Supported and Conventional Metal Ceramic Fixed Partial Dentures Before and After Veneering

dc.contributor.authorÖZKAN, YASEMİN
dc.contributor.authorsVarol, Seda; Kulak-Ozkan, Yasemin
dc.date.accessioned2022-03-13T12:47:05Z
dc.date.accessioned2026-01-11T16:09:33Z
dc.date.available2022-03-13T12:47:05Z
dc.date.issued2015
dc.description.abstractPurposeTo compare marginal and internal fit between 3- and 4-unit press-on-metal (PoM) ceramic, zirconia-supported, and conventional metal ceramic fixed partial dentures (FPDs) before and after veneering. Materials and MethodsTen pieces for each 3- and 4-unit MC, IPS InLine PoM, and IPS e.max ZirCAD/Zir Press FPDs were produced. Cross-sections from silicone replicas were examined and measured with a light microscope. Occlusal, axial, intermarginal, and marginal mean adaptation scores of cross-sectioned replicas and means of measurements obtained from 4 sites were calculated independently. ResultsMean values for molars were 78.44 32.01 m (MC), 89.84 +/- 29.20 m (PoM), and 85.17 +/- 28.49 m (Zir). Premolar values were 76.08 +/- 27.92 m (MC), 89.94 +/- 23.49 m (PoM), and 87.18 +/- 28.25 m (Zir). No difference existed between the means of 3- and 4-unit FPDs except the molar-intermarginal region. The mean value of 4-unit FPDs (93.88 +/- 25.41 m) was less than the 3-unit FPDs (103.68 +/- 24.55 m) at the molar-inter marginal region. A gap increase was observed in all sites except the molar-axio-occlusal region after veneering. According to the mean difference, gap increases at the molar-marginal, molar-intermarginal, and premolar-intermarginal regions were statistically significant. A statistical difference was found at the molar-marginal region for 4-unit MCR (p = 0.041) and 4-unit PoM FPDs (p = 0.042) before and after veneering. Gap increase after veneering of 4-unit metal ceramics at molar-intermarginal, premolar-marginal, and premolar-intermarginal regions (p = 0.020; p = 0.015; p = 0.004) was significant. ConclusionThe gap measurements of the IPS InLine PoM and IPS e.max ZirCAD/Zir Press groups were all clinically acceptable. No studies on marginal and internal fit in the IPS InLine PoM system have been published to date. This study should be supported with future studies. No significant increase was observed after press-veneering the IPS e.max ZirCAD frameworks with an IPS e.max ZirPress material; therefore, we recommend the use of this combination.
dc.identifier.doi10.1111/jopr.12229
dc.identifier.eissn1532-849X
dc.identifier.issn1059-941X
dc.identifier.pubmed25274041
dc.identifier.urihttps://hdl.handle.net/11424/238022
dc.identifier.wosWOS:000358376400007
dc.language.isoeng
dc.publisherWILEY
dc.relation.ispartofJOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectPress-on metal ceramics
dc.subjectzirconia
dc.subjectconventional metal ceramics
dc.subjectveneering
dc.subjectmarginal and internal fit
dc.subjectDENTAL PROSTHESES
dc.subjectDISTORTION
dc.subjectADAPTATION
dc.subjectTHICKNESS
dc.subjectSTRENGTH
dc.subjectSYSTEMS
dc.titleIn Vitro Comparison of Marginal and Internal Fit of Press-on-Metal Ceramic (PoM) Restorations with Zirconium-Supported and Conventional Metal Ceramic Fixed Partial Dentures Before and After Veneering
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage393
oaire.citation.issue5
oaire.citation.startPage387
oaire.citation.titleJOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY
oaire.citation.volume24

Files