Publication:
Is it difficult to obtain inter-observer agreement in the measurement of the beta angle in ultrasound evaluation of the paediatric hip?

dc.contributor.authorsKarakus, Ozgun; Karaman, Ozgur; Sari, Ahmet Sinan; Orak, Mehmet Mufit; Muratli, Hasan Hilmi
dc.date.accessioned2022-03-14T09:15:14Z
dc.date.accessioned2026-01-11T15:25:48Z
dc.date.available2022-03-14T09:15:14Z
dc.date.issued2019-12
dc.description.abstractIntroduction: The aim of this study was to determine the differences and consistencies in the morphological and angular interpretations of standard USG images. Therefore, it was aimed to show the correlations of orthopaedic doctors with different periods of experience in hip ultrasound measurements taken with the Graf method. Materials and methods: The study included 210 infants randomly selected from those who presented at our hospital for DDH screening. A total of 6 ultrasound images were taken for each hip. These images were evaluated by two paediatric orthopaedic professors, two orthopaedic specialists and two orthopaedic residents. The correlations of these measurements between all the doctors were evaluated statistically. Results: In beta angle evaluation, agreement between all the evaluators was at the level of 0.054. No agreement was seen between the two residents or between the two specialists (p=0.003, p=0.998, p=0.998, respectively). Agreement between the two professors was determined at the level of 0.508 (p<0.001). Agreement was determined at the level of 0.066 between the specialists and the residents. No agreement was observed between the specialists and the professors or between the professors and the residents (p=0.014, p=0.098, p=0.737, respectively). Conclusions: It can be concluded that greater emphasis on the beta angle, the cartilage labrum, and more detailed explanations of this subject in the resident training program will achieve standardisation on this subject, and this is in direct proportion to clinical experience.
dc.identifier.doi10.1186/s13018-019-1263-1
dc.identifier.issn1749-799X
dc.identifier.pubmed31315640
dc.identifier.urihttps://hdl.handle.net/11424/242856
dc.identifier.wosWOS:000475950500001
dc.language.isoeng
dc.publisherBMC
dc.relation.ispartofJOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCongenital hip dysplasia
dc.subjectUltrasonography
dc.subjectBeta angle
dc.subjectGraf method
dc.subjectDEVELOPMENTAL DYSPLASIA
dc.subjectULTRASONOGRAPHY
dc.subjectDIAGNOSIS
dc.subjectCLASSIFICATION
dc.subjectINFANTS
dc.subjectGRAF
dc.subjectRISK
dc.titleIs it difficult to obtain inter-observer agreement in the measurement of the beta angle in ultrasound evaluation of the paediatric hip?
dc.typearticle
dspace.entity.typePublication
oaire.citation.titleJOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH
oaire.citation.volume14

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
693.62 KB
Format:
Adobe Portable Document Format