Publication:
Comparative Analysis of Anterior Segment Parameters in Normal and Keratoconus Eyes Generated by Scheimpflug Tomography

dc.contributor.authorTOKER, AYŞE EBRU
dc.contributor.authorsOrucoglu, Faik; Toker, Ebru
dc.date.accessioned2022-03-14T11:08:36Z
dc.date.accessioned2026-01-11T17:32:23Z
dc.date.available2022-03-14T11:08:36Z
dc.date.issued2015
dc.description.abstractPurpose. To assess and compare the anterior and posterior corneal surface parameters, keratoconus indices, thickness profile data, and data from enhanced elevation maps of keratoconic and normal corneas with the Pentacam Scheimpflug corneal tomography and to determine the sensitivity and specificity of these parameters in discriminating keratoconus from normal eyes. Methods. The study included 656 keratoconus eyes and 515 healthy eyes with a mean age of 30.95 +/- 9.25 and 32.90 +/- 14.78 years, respectively. Forty parameters obtained from the Pentacam tomography were assessed by the receiver operating characteristic curve analysis for their efficiency. Results. Receiver operating characteristic curve analyses showed excellent predictive accuracy (area under the curve, ranging from 0.914 to 0.972) for 21 of the 40 parameters evaluated. Among all parameters indices of vertical asymmetry, keratoconus index, front elevation at thinnest location, back elevation at thinnest location, Ambrosio Relational Thickness (ARTmax), deviation of average pachymetric progression, deviation of ARTmax, and total deviation showed excellent (>90%) sensitivity and specificity in addition to excellent area under the receiver operating characteristic curve (AUROC). Conclusions. Parameters derived from the topometric and Belin-Ambrosio enhanced ectasia display maps very effectively discriminate keratoconus from normal corneas with excellent sensitivity and specificity.
dc.identifier.doi10.1155/2015/925414
dc.identifier.eissn2090-0058
dc.identifier.issn2090-004X
dc.identifier.pubmed25878897
dc.identifier.urihttps://hdl.handle.net/11424/245954
dc.identifier.wosWOS:000352390600001
dc.language.isoeng
dc.publisherHINDAWI LTD
dc.relation.ispartofJOURNAL OF OPHTHALMOLOGY
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectPOSTERIOR CORNEAL ELEVATION
dc.subjectTHINNEST POINT
dc.subjectINDEXES
dc.subjectPACHYMETRY
dc.subjectTHICKNESS
dc.subjectVOLUME
dc.titleComparative Analysis of Anterior Segment Parameters in Normal and Keratoconus Eyes Generated by Scheimpflug Tomography
dc.typearticle
dspace.entity.typePublication
oaire.citation.titleJOURNAL OF OPHTHALMOLOGY
oaire.citation.volume2015

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
4.46 MB
Format:
Adobe Portable Document Format