Publication:
Analysis of endoscopic third ventriculostomy patency by MRI: value of different pulse sequences, the sequence parameters, and the imaging planes for investigation of flow void

dc.contributor.authorsDincer, Alp; Yildiz, Erdem; Kohan, Saeed; Ozek, M. Memet
dc.date.accessioned2022-03-12T17:53:35Z
dc.date.accessioned2026-01-10T17:18:08Z
dc.date.available2022-03-12T17:53:35Z
dc.date.issued2011
dc.description.abstractThe aim of the study is to evaluate the efficiency of turbo spin-echo (TSE), three-dimensional constructive interference in the steady state (3D CISS) and cine phase contrast (Cine PC) sequences in determining flow through the endoscopic third ventriculostomy (ETV) fenestration, and to determine the effect of various TSE sequence parameters. The study was approved by our institutional review board and informed consent from all patients was obtained. Two groups of patients were included: group I (24 patients with good clinical outcome after ETV) and group II (22 patients with hydrocephalus evaluated preoperatively). The imaging protocol for both groups was identical. TSE T2 with various sequence parameters and imaging planes, and 3D CISS, followed by cine PC were obtained. Flow void was graded as four-point scales. The sensitivity, specificity, accuracy, positive and negative predictive values of sequences were calculated. Bidirectional flow through the fenestration was detected in all group I patients by cine PC. Stroke volumes through the fenestration in group I ranged 10-160.8 ml/min. There was no correlation between the presence of reversed flow and flow void grading. Also, there was no correlation between the stroke volumes and flow void grading. The sensitivity of 3D CISS was low, and 2 mm sagittal TSE T2, nearly equal to cine PC, provided best result. Cine PC and TSE T2 both have high confidence in the assessment of the flow through the fenestration. But, sequence parameters significantly affect the efficiency of TSE T2.
dc.identifier.doi10.1007/s00381-010-1219-6
dc.identifier.issn0256-7040
dc.identifier.pubmed20632013
dc.identifier.urihttps://hdl.handle.net/11424/230472
dc.identifier.wosWOS:000285786900019
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofCHILDS NERVOUS SYSTEM
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectEndoscopic third ventriculostomy
dc.subjectFenestration patency
dc.subjectFlow void
dc.subjectTSE
dc.subjectCine PC
dc.subjectCINE PHASE-CONTRAST
dc.subjectCSF FLOW
dc.subjectOBSTRUCTIVE HYDROCEPHALUS
dc.subjectFUNCTIONAL-ANALYSIS
dc.subjectARTIFACT REDUCTION
dc.subjectOUTCOME ANALYSIS
dc.subjectSTEADY-STATE
dc.subjectMANAGEMENT
dc.titleAnalysis of endoscopic third ventriculostomy patency by MRI: value of different pulse sequences, the sequence parameters, and the imaging planes for investigation of flow void
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage135
oaire.citation.issue1
oaire.citation.startPage127
oaire.citation.titleCHILDS NERVOUS SYSTEM
oaire.citation.volume27

Files