Effect of short curing times with a high-intensity light-emitting diode or high-power halogen on shear bond strength of metal brackets before and after thermocycling

dc.contributor.authorsCerekja, Erion; Cakirer, Banu
dc.date.accessioned2022-03-14T09:25:24Z
dc.date.accessioned2026-01-11T05:58:36Z
dc.date.available2022-03-14T09:25:24Z
dc.date.issued2011-05
dc.description.abstractObjective: To test the hypothesis that short curing times using a high-intensity light-emitting diode (LED) or high-power halogen are not associated with compromised shear bond strength (SBS) of metal brackets before and after thermocycling. Materials and Methods: Two hundred forty extracted human premolar teeth were divided into six groups of 40 each. Metal brackets were bonded using a light-cured composite (Transbond XT). In group 1 a conventional halogen light (Hi lux) was used for 40 seconds. In groups 2, 3, and 4 a high-power halogen light (Swiss Master) was used for 2, 3, and 6 seconds, respectively. In groups 5 and 6 a high-intensity LED (Bluephase) was used for 10 and 20 seconds, respectively. After bonding, half of the specimens in each group were thermocycled, and all specimens were tested for SBS. After debonding, the bracket bases and the enamel surfaces were scored according to the Adhesive Remnant Index. Results: Two-way analysis of variance detected significant differences in SBS values with respect to curing method (type of light-curing unit and curing time) (P = .0001) and thermocycling (P = .01). Tukey post hoc analysis showed that with or without thermocycling the mean SBS values of groups 1, 4, 5, and 6 were not significantly different, whereas group 2 showed the lowest SBS values. The predominant failure site for groups 2 and 3 was between the bracket and the adhesive and for groups 4, 5, 6 it was at the tooth/adhesive interface. Conclusion: Curing time can be reduced to 6 seconds with high-power halogen light and to 10 seconds with high-intensity LED without compromising in vitro SBS of metal brackets. (Angle Orthod. 2011;81:510-516.)
dc.identifier.doi10.2319/071810-412.1
dc.identifier.issn0003-3219
dc.identifier.pubmed21261490
dc.identifier.urihttps://hdl.handle.net/11424/243103
dc.identifier.wosWOS:000289761800022
dc.language.isoeng
dc.publisherE H ANGLE EDUCATION RESEARCH FOUNDATION, INC
dc.relation.ispartofANGLE ORTHODONTIST
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectLight-emitting diode
dc.subjectHalogen
dc.subjectORTHODONTIC BRACKETS
dc.subjectPOLYMERIZATION TIMES
dc.subjectRESIN COMPOSITE
dc.subjectADHESIVE
dc.subjectDENSITY
dc.subjectUNITS
dc.subjectCURE
dc.titleEffect of short curing times with a high-intensity light-emitting diode or high-power halogen on shear bond strength of metal brackets before and after thermocycling
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage516
oaire.citation.issue3
oaire.citation.startPage510
oaire.citation.titleANGLE ORTHODONTIST
oaire.citation.volume81