Publication:
Meniscal repair using large diameter horizontal sutures increases fixation strength: an in vitro study

dc.contributor.authorsKocabey, Yavuz; Taser, Omer; Hapa, Onur; Guclu, Aycan; Bozdag, Ergun; Sunbuloglu, Emin; Doral, MahmutNedim
dc.date.accessioned2022-03-12T18:05:03Z
dc.date.accessioned2026-01-11T08:02:23Z
dc.date.available2022-03-12T18:05:03Z
dc.date.issued2011
dc.description.abstractThe purpose of this study was to compare the mechanical characteristics of meniscal repair fixation using horizontal sutures and two different diameter sutures under submaximal cyclic and load to failure test conditions. A 2-cm long anteroposterior vertical longitudinal incision was created in two groups of bovine medial menisci. Lesions were repaired using either #2-0 (Group 1), or #2 (Group 2) Fiberwire suture. Following repair, the lesion was extended through the posterior and anterior meniscal horns so that no tissue secured the repair site. Specimens underwent submaximal cyclic (5-50 N at 1 Hz for 500 cycles) and load to failure testing (5 mm/min crosshead speed) in a servo hydraulic device. Specimen failure mode was verified by the primary investigator. An alpha level of P < 0.05 was selected to indicate statistical significance. Group 2 displayed greater load at failure (132.1 +/- A 54.4 N) than Group 1 (91.9 +/- A 26.2 N) (P = 0.02). Group 2 also displayed greater stiffness (47.1 +/- A 8.3 N/mm) than Group 1 (38.5 +/- A 10.2 N/mm) (P = 0.03). The failure mode for all specimens was suture pull-through the meniscal tissue. Larger diameter suture provided superior mechanical meniscal fixation. If Horizontal suture would be used in meniscal repair, the most suitable larger diameter suture should be used.
dc.identifier.doi10.1007/s00167-010-1203-4
dc.identifier.issn0942-2056
dc.identifier.pubmed20602087
dc.identifier.urihttps://hdl.handle.net/11424/230577
dc.identifier.wosWOS:000286436400011
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofKNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectMeniscus
dc.subjectHorizontal suture
dc.subjectSuture diameter
dc.subjectPULL-OUT
dc.subjectFAILURE STRENGTHS
dc.subjectREHABILITATION
dc.subjectSYSTEMS
dc.subjectDEVICES
dc.subjectKNEES
dc.subjectLOAD
dc.subjectFIX
dc.titleMeniscal repair using large diameter horizontal sutures increases fixation strength: an in vitro study
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage206
oaire.citation.issue2
oaire.citation.startPage202
oaire.citation.titleKNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
oaire.citation.volume19

Files