Publication:
Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures

dc.contributor.authorsTaskonak, Burak; Sertgoez, Atilla
dc.date.accessioned2022-03-12T17:21:03Z
dc.date.accessioned2026-01-10T17:52:31Z
dc.date.available2022-03-12T17:21:03Z
dc.date.issued2006
dc.description.abstractObjectives. The aim of this study was to evaluate the clinical performance of crowns and fixed partial dentures (FPDs) made with the Empress 2 system over a 2-year period. Methods. Twenty anterior or posterior all-ceramic (Empress 2) crowns and 20 anterior or posterior, three-unit fixed partial dentures were fabricated for 15 patients. Evaluations of the restorations were performed at baseline and once a year during the 2-year follow-up period. U.S. Public Health Service criteria were used to examine the marginal adaptation, color match, secondary caries and visible fractures in the restorations. Survival rate of the restorations were determined using Kaplan-Meier statistical analysis. Results. U.S. Public Health Service criteria showed 100% Alpha scores concerning recurrent caries for both crowns and FPDs. No crown fractures were observed during the 2-year follow-up, however, 10 (50%) catastrophic failures of FPDs occurred. Five (25%) failures occurred within the 1-year clinical period and the others (25%) within the second year. Significance. Single unit Empress 2 all-ceramic crowns exhibited a satisfactory clinical performance over 2-year period. Furthermore, the high fracture rate of Empress 2 FPDs limits the usage of Empress 2 for the fabrication of all-ceramic FPD. (C) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.dental.2005.11.028
dc.identifier.eissn1879-0097
dc.identifier.issn0109-5641
dc.identifier.pubmed16375961
dc.identifier.urihttps://hdl.handle.net/11424/228308
dc.identifier.wosWOS:000241746900005
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofDENTAL MATERIALS
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectdental ceramic
dc.subjectclinical evaluation
dc.subjectfailure of fixed partial dentures
dc.subjectSTRENGTH
dc.subjectMETAANALYSIS
dc.subjectLAYER
dc.titleTwo-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage1013
oaire.citation.issue11
oaire.citation.startPage1008
oaire.citation.titleDENTAL MATERIALS
oaire.citation.volume22

Files