Publication: Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures
| dc.contributor.authors | Taskonak, Burak; Sertgoez, Atilla | |
| dc.date.accessioned | 2022-03-12T17:21:03Z | |
| dc.date.accessioned | 2026-01-10T17:52:31Z | |
| dc.date.available | 2022-03-12T17:21:03Z | |
| dc.date.issued | 2006 | |
| dc.description.abstract | Objectives. The aim of this study was to evaluate the clinical performance of crowns and fixed partial dentures (FPDs) made with the Empress 2 system over a 2-year period. Methods. Twenty anterior or posterior all-ceramic (Empress 2) crowns and 20 anterior or posterior, three-unit fixed partial dentures were fabricated for 15 patients. Evaluations of the restorations were performed at baseline and once a year during the 2-year follow-up period. U.S. Public Health Service criteria were used to examine the marginal adaptation, color match, secondary caries and visible fractures in the restorations. Survival rate of the restorations were determined using Kaplan-Meier statistical analysis. Results. U.S. Public Health Service criteria showed 100% Alpha scores concerning recurrent caries for both crowns and FPDs. No crown fractures were observed during the 2-year follow-up, however, 10 (50%) catastrophic failures of FPDs occurred. Five (25%) failures occurred within the 1-year clinical period and the others (25%) within the second year. Significance. Single unit Empress 2 all-ceramic crowns exhibited a satisfactory clinical performance over 2-year period. Furthermore, the high fracture rate of Empress 2 FPDs limits the usage of Empress 2 for the fabrication of all-ceramic FPD. (C) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved. | |
| dc.identifier.doi | 10.1016/j.dental.2005.11.028 | |
| dc.identifier.eissn | 1879-0097 | |
| dc.identifier.issn | 0109-5641 | |
| dc.identifier.pubmed | 16375961 | |
| dc.identifier.uri | https://hdl.handle.net/11424/228308 | |
| dc.identifier.wos | WOS:000241746900005 | |
| dc.language.iso | eng | |
| dc.publisher | ELSEVIER SCI LTD | |
| dc.relation.ispartof | DENTAL MATERIALS | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | dental ceramic | |
| dc.subject | clinical evaluation | |
| dc.subject | failure of fixed partial dentures | |
| dc.subject | STRENGTH | |
| dc.subject | METAANALYSIS | |
| dc.subject | LAYER | |
| dc.title | Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 1013 | |
| oaire.citation.issue | 11 | |
| oaire.citation.startPage | 1008 | |
| oaire.citation.title | DENTAL MATERIALS | |
| oaire.citation.volume | 22 |
