Publication:
Spiral-shaped metallic implant in the treatment of Achilles tendon ruptures: an experimental study on the Achilles tendon of sheep

dc.contributor.authorsErol, Bülent; Kocaoğlu, Bariş; Esemenli, Tanil
dc.date.accessioned2022-03-15T11:22:33Z
dc.date.accessioned2026-01-11T19:07:01Z
dc.date.available2022-03-15T11:22:33Z
dc.date.issued2007
dc.description.abstractThere are 2 main factors contributing to the strength of tendon repair: the tensile strength of the material used in repair and the tendon-holding capacity of the suture configuration. In the current study, we aimed to find a technique with high repair strength by increasing both the tensile strength of the material and the tendon-holding capacity of the configuration. We developed metal implants (models 1 and 2) made from stainless-steel wire with 2 different spiral-shaped configurations. We measured tendon-holding capacities of these alternative implants biomechanically and compared them with frequently used suture techniques, the Bunnell and locking loop, which were achieved with 5 Ticron sutures. Sixty-four sheep Achilles' tendons were used in the study as 16 tendons in each group. Model 2 was more resistant to deformation under loading when compared with model 1. The results demonstrated that model 2 was superior to model 1 and both suture techniques. This study could be accepted as a step for reaching a strong tendon repair technique. It should be emphasized that the technique needs to be improved technically to make it convenient for clinical use.
dc.identifier.doi10.1053/j.jfas.2006.10.008
dc.identifier.issn1067-2516
dc.identifier.pubmedPMID: 17466241
dc.identifier.urihttps://hdl.handle.net/11424/249788
dc.language.isoeng
dc.relation.ispartofThe Journal of Foot and Ankle Surgery: Official Publication of the American College of Foot and Ankle Surgeons
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAnimals
dc.subjectEquipment Design
dc.subjectEquipment Failure
dc.subjectSuture Techniques
dc.subjectTensile Strength
dc.subjectModels, Animal
dc.subjectAchilles Tendon
dc.subjectStainless Steel
dc.subjectImplants, Experimental
dc.subjectSheep
dc.titleSpiral-shaped metallic implant in the treatment of Achilles tendon ruptures: an experimental study on the Achilles tendon of sheep
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage161
oaire.citation.startPage155
oaire.citation.titleThe Journal of Foot and Ankle Surgery: Official Publication of the American College of Foot and Ankle Surgeons
oaire.citation.volume3

Files