Publication:
Effect of length and diameter of tapered posts on the retention

dc.contributor.authorsNergiz, I; Schmage, P; Ozcan, M; Platzer, U
dc.date.accessioned2022-03-12T17:01:46Z
dc.date.accessioned2026-01-11T08:17:27Z
dc.date.available2022-03-12T17:01:46Z
dc.date.issued2002
dc.description.abstractThe force transmission of tapered unthreaded posts along the root has been reported to be homogenous but their retentive strength was found to be lower compared with those of parallel unthreaded or other kinds of threaded posts. The purpose of this in vitro study was to investigate the effect of length and diameter on the retentive strength of sandblasted tapered prefabricated titanium posts (Erlangen post system(R)). Posts with constant taper angle but with three different lengths (9, 12, 15 mm) and apical diameters (0.5, 0.9, 1.1 mm) were cemented using zinc phosphate cement into the prepared and roughened post spaces of 90 intact anterior teeth. The post retention concerning length and diameter, being independent from each other, was measured by a tensile force test. The retentive strength was found to be proportional to the length as well as to the diameter of the posts. The mean minimum strength (181+/-14 N) recorded for the thinnest and shortest post was significantly lower than that of mean maximum strength (612+/-85 N) obtained from those of the thickest and longest post. Proportional bond strengths of the posts comprising their surface areas ranged between 6.8 and 7.9 N mm(-2) which were not significantly different between any group. The retention was effected strongly with the increase in the length (approximately 100%) than with the increase in the diameter (approximately 60%). Concerning the posts tested in this study, it is concluded that some caution should be exercised in the choice of post with appropriate length rather than diameter for the tooth concerned.
dc.identifier.doi10.1046/j.1365-2842.2002.00806.x
dc.identifier.issn0305-182X
dc.identifier.pubmed11844029
dc.identifier.urihttps://hdl.handle.net/11424/227411
dc.identifier.wosWOS:000173321800005
dc.language.isoeng
dc.publisherBLACKWELL PUBLISHING LTD
dc.relation.ispartofJOURNAL OF ORAL REHABILITATION
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectprefabricated post
dc.subjectpost size
dc.subjectretention
dc.subjectENDODONTICALLY TREATED TEETH
dc.subjectSTRESS-DISTRIBUTION
dc.subjectCORE SYSTEMS
dc.subjectRESTORATION
dc.subjectDESIGN
dc.subjectDOWELS
dc.subjectPHILOSOPHIES
dc.subjectRESISTANCE
dc.subjectFRACTURE
dc.subjectSTRENGTH
dc.titleEffect of length and diameter of tapered posts on the retention
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage34
oaire.citation.issue1
oaire.citation.startPage28
oaire.citation.titleJOURNAL OF ORAL REHABILITATION
oaire.citation.volume29

Files