Publication:
Measurements of serum procollagen-III peptide and M30 do not improve the diagnostic accuracy of transient elastography for the detection of hepatic fibrosis in patients with nonalcoholic fatty liver disease

dc.contributor.authorsErgelen, Rabia; Akyuz, Umit; Aydin, Yucel; Eren, Fatih; Yilmaz, Yusuf
dc.date.accessioned2022-03-13T12:49:57Z
dc.date.accessioned2026-01-11T17:40:24Z
dc.date.available2022-03-13T12:49:57Z
dc.date.issued2015
dc.description.abstractBackground Transient elastography (TE) has recently emerged as an accurate noninvasive imaging method for the diagnosis of liver fibrosis in nonalcoholic fatty liver disease (NAFLD). Here, we tested whether adding serum measures of serum procollagen-III peptide (PIIIP) and caspase-cleaved cytokeratin 18 fragment (M30) to TE could improve its diagnostic accuracy in patients with biopsy-proven NAFLD. Patients and methods TE was performed in 87 patients with NAFLD. Serum PIIIP and M30 levels were determined by enzyme-linked immunosorbent assay. Liver histology was considered the gold standard. The diagnostic accuracies were assessed by measuring the area under the receiver operating curve. Results At histopathological examination, 34 patients (39.1%) had significant fibrosis (F2-F4) and 19 patients (21.8%) had advanced fibrosis (F3-F4). Both TE and serum M30 levels were independent predictors of fibrosis, whereas no association was found with PIIIP. No significant differences in terms of sensitivity and specificity for both significant and advanced fibrosis were evident for TE, serum M30, or their combination. Moreover, the area under the receiver operating curves of serum M30 combined with TE did not differ significantly from those of either test alone. Conclusion Both TE and serum M30 levels are accurate for the noninvasive diagnosis of fibrosis in NAFLD. However, their combination did not improve the overall diagnostic accuracy. Copyright (c) 2015 Wolters Kluwer Health, Inc. All rights reserved.
dc.identifier.doi10.1097/MEG.0000000000000342
dc.identifier.eissn1473-5687
dc.identifier.issn0954-691X
dc.identifier.pubmed25923941
dc.identifier.urihttps://hdl.handle.net/11424/238326
dc.identifier.wosWOS:000353688400009
dc.language.isoeng
dc.publisherLIPPINCOTT WILLIAMS & WILKINS
dc.relation.ispartofEUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectaccuracy
dc.subjectbiomarkers
dc.subjectfibroscan
dc.subjectfibrosis
dc.subjectnonalcoholic fatty liver disease
dc.subjecttransient elastography
dc.subjectSTEATOHEPATITIS
dc.subjectVALIDATION
dc.subjectSTEATOSIS
dc.subjectCIRRHOSIS
dc.subjectBIOPSY
dc.subjectNAFLD
dc.subjectNASH
dc.titleMeasurements of serum procollagen-III peptide and M30 do not improve the diagnostic accuracy of transient elastography for the detection of hepatic fibrosis in patients with nonalcoholic fatty liver disease
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage671
oaire.citation.issue6
oaire.citation.startPage667
oaire.citation.titleEUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY
oaire.citation.volume27

Files