Publication: Biomedical porous Ti-16Nb-10Zr-(0-15)Ta alloys
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
CARL HANSER VERLAG
Abstract
To improve the properties of compact Ti alloys for biomedical applications, porous Ti-16Nb-10Zr-(0-15)Ta (wt.%) alloys were produced by the space-holding method using an ammonium hydrogen carbonate space holder. The pore size distribution, porosity ratio and mechanical properties of the obtained porous alloys were investigated. Also, the effect of Ta addition on the microstructure and mechanical properties was investigated. It has been determined that the sintered porous Ti-Nb-Zr-Ta alloys have suitable mechanical properties (elastic modulus: 36.32-38 GPa, transverse rupture strength: 154-281 MPa) for hard tissue implants.