Publication: Linear regression modeling based scoring system to reduce benign breast biopsies using multi-parametric US with color doppler and SWE
Loading...
Files
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Rationale and Objectives: To develop a simple ultrasound (US) based scoring system to reduce benign breast biopsies.
Materials and Methods: Women with BI-RADS 4 or 5 breast lesions underwent shear-wave elastography (SWE) imaging before biopsy.
Standard US and color Doppler US (CDUS) parameters were recorded, and the size ratio (SzR=longest/shortest diameter) was calculated.
Measured/calculated SWE parameters were minimum (SWVMin) and maximum (SWVMax) shear velocity, velocity heterogeneity
(SWVH=SWVMax-SWVMin), velocity ratio (SWVR=SWVMin/SWVMax), and normalized SWVR (SWVRn=(SWVMax-SWVMin)/SWVMin). Linear
regression analysis was performed by converting continuous parameters into categorical corresponding equivalents using decision tree
analyses. Linear regression models were fitted using stepwise regression analysis and optimal coefficients for the predictors in the models
were determined. A scoring model was devised from the results and validated using a different data set from another center consisting of
187 cases with BI-RADS 3, 4, and 5 lesions.
Results: A total of 418 lesions (238 benign, 180 malignant) were analyzed. US and CDUS parameters exhibited poor (AUC=0.592-0.696),
SWE parameters exhibited poor-good (AUC=0.607-0.816) diagnostic performance in benign/malignant discrimination. Linear regression
models of US+CDUS and US+SWE parameters revealed an AUC of 0.819 and 0.882, respectively. The developed scoring system could
have avoided biopsy in 37.8% of benign lesions while missing 1.1% of malignant lesions. The scoring system was validated with a 100%
NPV rate with a specificity of 74.6%.
Conclusion: The linear regression model using US+SWE parameters performed better than any single parameter alone. The developed
scoring method could lead to a significant decrease in benign biopsies.
Description
Citation
Demirci B. Ö., Buğdaycı O., Ertaş G., Şanlı D. E. T., Kaya H., Arıbal E., "Linear Regression Modeling Based Scoring System to Reduce Benign Breast Biopsies Using Multi-parametric US with Color Doppler and SWE.", Academic radiology, 2023