Publication: Experimental Custom-Made Zirconia Abutments for Narrow Implants in Esthetically Demanding Regions: A 5-year Follow-Up
| dc.contributor.authors | Vanlioglu, Burcin Akoglu; Ozkan, Yasar; Evren, Buket; Ozkan, Yasemin Kulak | |
| dc.date.accessioned | 2022-03-12T18:05:28Z | |
| dc.date.accessioned | 2026-01-11T07:16:12Z | |
| dc.date.available | 2022-03-12T18:05:28Z | |
| dc.date.issued | 2012 | |
| dc.description.abstract | Purpose: This prospective clinical study evaluated an experimental custom-made zirconia abutment with respect to peri-implant hard and soft tissue reaction in narrow implants. Materials and Methods: Patients were treated with prefabricated titanium implants and custom-made zirconia abutments. All-ceramic crowns were fabricated and cemented with resin cement. Clinical parameters such as Plaque Index, Sulcus Bleeding Index, peri-implant probing depth, and radiographic marginal bone loss levels were recorded, along with any biologic and mechanical complications, at baseline and up to 5 years. Results: Twelve patients with missing maxillary lateral incisors treated with a total of 23 implants were evaluated. Thirteen Straumann Narrow Neck Solid Screw implants with a diameter of 3.3 mm and 10 Astra Micro Thread implants with a diameter of 3.5 mm were used. Six patients with 11 implants were treated with custom-made zirconia abutments and prefabricated metal abutments were used in the control group. Implant and abutment success at 5 years was 100%. No abutment fractures occurred. Abutment screw loosening was reported for one restoration at the 1-year recall. Mean marginal bone loss measured 0.21 mm after 5 years of functional loading. Conclusion: Custom-made zirconia abutments offered sufficient stability to support all-ceramic restorations over narrow implants in anterior regions over a 5-year period. The soft and hard tissue reactions to zirconia were favorable. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:1239-1242 | |
| dc.identifier.doi | doiWOS:000310395900032 | |
| dc.identifier.eissn | 1942-4434 | |
| dc.identifier.issn | 0882-2786 | |
| dc.identifier.pubmed | 23057040 | |
| dc.identifier.uri | https://hdl.handle.net/11424/230694 | |
| dc.identifier.wos | WOS:000310395900032 | |
| dc.language.iso | eng | |
| dc.publisher | QUINTESSENCE PUBLISHING CO INC | |
| dc.relation.ispartof | INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | clinical follow-up | |
| dc.subject | full ceramic crowns | |
| dc.subject | narrow implants | |
| dc.subject | zirconia abutment | |
| dc.title | Experimental Custom-Made Zirconia Abutments for Narrow Implants in Esthetically Demanding Regions: A 5-year Follow-Up | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 1242 | |
| oaire.citation.issue | 5 | |
| oaire.citation.startPage | 1239 | |
| oaire.citation.title | INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS | |
| oaire.citation.volume | 27 |
