Publication:
Flow Cytometric Detection of Anti-AB Antibody Titers in Blood Group O Recipients of Blood Group A2 Donor Kidneys

dc.contributor.authorATA, PINAR
dc.contributor.authorsAta, P.; Cetinkaya, F.; Ozgezer, T.; Ozel, L.; Tulunay, A.; Eksioglu, E.; Titiz, M. I.
dc.date.accessioned2022-03-12T16:13:55Z
dc.date.accessioned2026-01-11T15:09:53Z
dc.date.available2022-03-12T16:13:55Z
dc.date.issued2012
dc.description.abstractAim. ABO-incompatible kidney transplantation has been accepted for end-stage renal failure patients who have no ready opportunity for a deceased or living donor. Antibody titration for ABO-incompatible renal transplantation is not only difficult but also lacks conformity among laboratories. Herein we analyzed 20 living related renal transplant couples to detect recipient anti-A2 antibody using flow cytometric analysis. Materials and methods. Patients were admitted to our center for renal transplantation between January 1999 and December 2010. All but four of them had undergone a previous renal transplantation from an ABO-compatible donor but experienced graft failure. All donor blood groups were subtyped by our blood bank using a lectin-based dilution assay. To detect recipient anti-A2 antibody titers we used a tube hemagglutination method. A/B antibody titer analysis by flow cytometry incubated serially diluted serum samples with donor erythrocytes. Each analysis was repeated three, times over a 2-week period using an older and the last sera simultaneously. Results. The 13 male and 7 female patients showed our overall mean age of 32 +/- 12 years. All patients had panel-reactive antibody levels below 15%. The level of flow cytometric antibody titers did not vary upon repeated analysis (P = .01). When compared with the tube method there was a discrepancy of the level at which the antibody titer became negative. Discussion. Flow cytometric antibody titration is a practical and rapid technique to determine the amount of anti-A2 antibody in renal recipients.
dc.identifier.doi10.1016/j.transproceed.2012.05.051
dc.identifier.issn0041-1345
dc.identifier.pubmed22841249
dc.identifier.urihttps://hdl.handle.net/11424/225150
dc.identifier.wosWOS:000307433400064
dc.language.isoeng
dc.publisherELSEVIER SCIENCE INC
dc.relation.ispartofTRANSPLANTATION PROCEEDINGS
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectINCOMPATIBLE-TRANSPLANTATION-COMMITTEE
dc.subjectTITRATION
dc.titleFlow Cytometric Detection of Anti-AB Antibody Titers in Blood Group O Recipients of Blood Group A2 Donor Kidneys
dc.typeconferenceObject
dspace.entity.typePublication
oaire.citation.endPage1709
oaire.citation.issue6
oaire.citation.startPage1706
oaire.citation.titleTRANSPLANTATION PROCEEDINGS
oaire.citation.volume44

Files