Publication: Interrater and Intrarater Reliability of Subcutaneous Echogenicity Grade and Subcutaneous Echo-Free Space Grade in Breast Cancer-Related Lymphedema
| dc.contributor.authors | Giray, Esra; Yagci, Ilker | |
| dc.date.accessioned | 2022-03-12T22:28:09Z | |
| dc.date.accessioned | 2026-01-11T08:29:07Z | |
| dc.date.available | 2022-03-12T22:28:09Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | Background: Subcutaneous echogenicity grade (SEG) and subcutaneous echo-free space (SEFS) grade allow semiquantitation of nonspecific subcutaneous tissue inflammation and fluid accumulation in breast cancer-related lymphedema. However, inter- and intrarater reliability of SEG and SEFS is yet to be reported. The objective of this study is to assess inter-rater and intrarater reliability of SEG and SEFS in patients with breast cancer-related lymphedema. Methods and Results: Two physiatrists performed SEG and SEFS grade to determine inter-rater and intrarater reliability. Inter-rater reliability for SEG and SEFS was excellent (Kappa [K] = 0.836, weighted Kappa [K-w] = 0.85; K = 0.884, K-w = 0.92). K and K-w values of SEG and SEFS grading systems indicated excellent intrarater reliability (K = 0.81, K-w = 0.83; K = 0.798, K-w = 0.82). This trial is registered with Clinicaltrials.gov, under number NCT03559296. Conclusions: Based on the findings of this study, SEG and SEFS demonstrated acceptable reliability. SEG and SEFS appear to be reliable and useful grading systems for the assessment of breast cancer-related lymphedema. | |
| dc.identifier.doi | 10.1089/lrb.2018.0053 | |
| dc.identifier.eissn | 1557-8585 | |
| dc.identifier.issn | 1539-6851 | |
| dc.identifier.pubmed | 30570358 | |
| dc.identifier.uri | https://hdl.handle.net/11424/235287 | |
| dc.identifier.wos | WOS:000490443000005 | |
| dc.language.iso | eng | |
| dc.publisher | MARY ANN LIEBERT, INC | |
| dc.relation.ispartof | LYMPHATIC RESEARCH AND BIOLOGY | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | arm | |
| dc.subject | breast cancer | |
| dc.subject | echogenicity | |
| dc.subject | lymphedema | |
| dc.subject | subcutaneous tissue | |
| dc.subject | ultrasound | |
| dc.subject | CLINICAL MEASURES | |
| dc.subject | SEVERITY | |
| dc.subject | ULTRASONOGRAPHY | |
| dc.subject | ULTRASOUND | |
| dc.subject | VOLUME | |
| dc.title | Interrater and Intrarater Reliability of Subcutaneous Echogenicity Grade and Subcutaneous Echo-Free Space Grade in Breast Cancer-Related Lymphedema | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 524 | |
| oaire.citation.issue | 5 | |
| oaire.citation.startPage | 518 | |
| oaire.citation.title | LYMPHATIC RESEARCH AND BIOLOGY | |
| oaire.citation.volume | 17 |