Publication: Diagnostic value of effluent endotoxin level in gram-negative peritonitis in CAPD patients
| dc.contributor.authors | Muhammed K.O., Özener C., Akoglu E. | |
| dc.date.accessioned | 2022-03-15T01:54:12Z | |
| dc.date.accessioned | 2026-01-11T08:55:18Z | |
| dc.date.available | 2022-03-15T01:54:12Z | |
| dc.date.issued | 2001 | |
| dc.description.abstract | ◆ Objective: To evaluate the diagnostic usefulness of effluent endotoxin by Limulus amoebocyte lysate (LAL) assay in gram-negative peritonitis patients on continuous ambulatory peritoneal dialysis (CAPD) therapy. ◆ Design: Prospective study with patients serving as their own controls. Standard microbiologic work up and endotoxin analysis of effluents (night dwell) were done during the pre- and posttreatment phases. ◆ Setting: Specimens from three teaching hospitals were processed and tested at a common center. Patients were left for treatment at their respective centers without intervention. ◆ Patients: 32 clinical peritonitis and 40 infection-free CAPD patients were studied. ◆ Results: 75% (n = 24) of cultures were positive: 41.6% (n = 10) gram-negative and 58.4% (n = 14) gram-positive bacteria. Effluents of pre- and post treated gram-negative cultures had endotoxin levels of 1.53 ± 0.169 and 0.214 ± 0.085 endotoxin units (EU)/mL, respectively (p < 0.0001); pre- and posttreated gram-positive levels of 0.102 ± 0.06 and 0.122 ± 0.052 EU/mL, respectively (p > 0.05); pre- and posttreated culture-negative peritonitis levels of 0.110 ± 0.025 and 0.087 ± 0.031 EU/mL, respectively (p > 0.05); peritonitis-free effluents contained 0.117 ± 0.079 EU/mL. The diagnostic specificity and the sensitivity of LAL assay were 100% and 98.2% respectively. ◆ Conclusion: Where initial microbiological work-up cannot demonstrate a pathogen, effluent endotoxin determined by quantitative LAL assay is a useful marker for diagnosis and management, within safe time limits, of gram-negative peritonitis in CAPD patients. | |
| dc.identifier.doi | 10.1177/089686080102100208 | |
| dc.identifier.issn | 8968608 | |
| dc.identifier.pubmed | 11330559 | |
| dc.identifier.uri | https://hdl.handle.net/11424/246485 | |
| dc.language.iso | eng | |
| dc.publisher | Multimed Inc. | |
| dc.relation.ispartof | Peritoneal Dialysis International | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Endotoxin | |
| dc.subject | Gram-negative bacteria | |
| dc.subject | LAL | |
| dc.subject | Limulus amoebocyte lysate | |
| dc.subject | Peritonitis | |
| dc.title | Diagnostic value of effluent endotoxin level in gram-negative peritonitis in CAPD patients | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 157 | |
| oaire.citation.issue | 2 | |
| oaire.citation.startPage | 154 | |
| oaire.citation.title | Peritoneal Dialysis International | |
| oaire.citation.volume | 21 |