Publication: Reference jitter values for the sternocleidomastoid muscle with concentric needle electrodes
| dc.contributor.author | ULUÇ, KAYIHAN | |
| dc.contributor.author | KAHRAMAN KOYTAK, PINAR | |
| dc.contributor.author | TANRIDAĞ, TÜLİN | |
| dc.contributor.authors | Kula, Ezgi; Tanridag, Tulin; Kahraman Koytak, Pinar; Uluc, Kayihan | |
| dc.date.accessioned | 2022-03-12T22:39:53Z | |
| dc.date.accessioned | 2026-01-11T09:01:10Z | |
| dc.date.available | 2022-03-12T22:39:53Z | |
| dc.date.issued | 2021 | |
| dc.description.abstract | Background The aim of this study was to establish reference jitter values for the voluntary activated sternocleidomastoid (SCM) muscle using a concentric needle electrode (CNE). Methods The study included 39 healthy participants (20 female and 19 male) aged 18-77 y. Jitter was expressed as the mean consecutive difference (MCD) of 80-100 consecutive discharges. Filters were set at 1 and 10 kHz. The mean MCDs for all participants were pooled, and the mean value +2.5 SD was accepted as the upper limit for the mean MCD. The upper limit for individual MCD was calculated using +2.5 SD of the upper 10th percentile MCD for individual participants. Results Mean age of the participants was 45 +/- 14.5 y. Mean MCD was 16.20 +/- 2.23 mu s (range: 12-21 mu s), and the upper limit of normal for mean MCD was 21.8 mu s. The mean value for 823 individual jitters was 23.3 +/- 4.61 mu s (range: 6.6-36.9 mu s), and the upper limit of normal for each individual jitter was 34.6 mu s. Conclusions The present findings indicate that upper normal limit for mean MCD is 22 mu s and for individual data it is 35 mu s. | |
| dc.identifier.doi | 10.1002/mus.27094 | |
| dc.identifier.eissn | 1097-4598 | |
| dc.identifier.issn | 0148-639X | |
| dc.identifier.pubmed | 33067804 | |
| dc.identifier.uri | https://hdl.handle.net/11424/235877 | |
| dc.identifier.wos | WOS:000583742900001 | |
| dc.language.iso | eng | |
| dc.publisher | WILEY | |
| dc.relation.ispartof | MUSCLE & NERVE | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | concentric needle electrode | |
| dc.subject | healthy participants | |
| dc.subject | jitter | |
| dc.subject | reference values | |
| dc.subject | sternocleidomastoid muscle | |
| dc.subject | SINGLE-FIBER EMG | |
| dc.subject | ELECTROMYOGRAPHY | |
| dc.title | Reference jitter values for the sternocleidomastoid muscle with concentric needle electrodes | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 119 | |
| oaire.citation.issue | 1 | |
| oaire.citation.startPage | 116 | |
| oaire.citation.title | MUSCLE & NERVE | |
| oaire.citation.volume | 63 |