Modelling and optimization of the firing zone of a tunnel kiln to predict the optimal feed locations and mass fluxes of the fuel and secondary air

dc.contributor.authorMANÇUHAN, EBRU
dc.contributor.authorKÜÇÜKADA, KURTUL
dc.contributor.authorsKaya, Sinem; Mancuhan, Ebru; Kuecuekada, Kurtul
dc.date.accessioned2022-03-12T17:37:07Z
dc.date.accessioned2026-01-10T19:40:17Z
dc.date.available2022-03-12T17:37:07Z
dc.date.issued2009
dc.description.abstractOptimization of the firing zone was done to minimize the fuel cost as being the objective function by finding the optimal operating variables. These variables are the initial admixed coal (AC) in the brick body, the mass flux and locations of pulverized coal (PC) and the secondary air required for complete combustion. The constraints are the carbon coming from the AC which increases the porosity of the bricks, and should be consumed completely. Two other constraints to avoid thermal shock are the temperature difference between bricks and air, and the maximum heating rate of the bricks. The results were compared to the plant data. (C) 2008 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.apenergy.2008.04.018
dc.identifier.eissn1872-9118
dc.identifier.issn0306-2619
dc.identifier.urihttps://hdl.handle.net/11424/229347
dc.identifier.wosWOS:000262219600007
dc.language.isoeng
dc.publisherELSEVIER SCI LTD
dc.relation.ispartofAPPLIED ENERGY
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectFiring zone
dc.subjectTunnel kiln
dc.subjectOptimization
dc.subjectPulverized coal
dc.subjectAdmixed coal
dc.titleModelling and optimization of the firing zone of a tunnel kiln to predict the optimal feed locations and mass fluxes of the fuel and secondary air
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage332
oaire.citation.issue3
oaire.citation.startPage325
oaire.citation.titleAPPLIED ENERGY
oaire.citation.volume86