dc.description.abstractCable joints are the weakest part of underground energy transmission systems due to the presence at the interface between the insulation material and the cable conductor. Underground cables serve under heavy service conditions (dust, dirt, humidity, etc.). So, the tracking resistance of polymers used in joint points of underground cables needs to be determined. In the first section of the study, equivalent samples were prepared under vacuum conditions in laboratory conditions from PU-based filling material used as filler material in low voltage underground cable joints. Prepared samples were tested in an established CTI test setup according to ASTM D5288. Samples were tested in prepared test setup under 600 V, 500 V, 400 V, and 300 V voltages. In the second section of the study, leakage currents were analyzed with the recurrence plot method, which is frequently used in nonlinear times series analysis. Later, recurrence quantification analysis was made by Recurrence Rate (RR) and Determinism (DET) parameters. The behavior of the system occurs less linear with decreased Recurrence Rate in Recurrence Quantification Analysis (RQA). RR and DET parameters increased with the decrease in voltage levels. As a result of, it is revealed that the tracking formation behavior of the PU cable joint becomes more unstable with increasing voltage. Thus, the CTI and RQA are shown to be also available to determine the tracking resistance of cable joints.
dc.identifier.citationİSPİRLİ M. M., ERSOY A., "The Application of Recurrence Plot in Tracking Characteristics of PU-Based Insulation Material", ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, cilt.47, sa.11, ss.13907-13915, 2022
dc.identifier.doi10.1007/s13369-022-06584-0
dc.identifier.endpage13915
dc.identifier.issn2193-567X
dc.identifier.issue11
dc.identifier.startpage13907
dc.identifier.urihttps://link.springer.com/article/10.1007/s13369-022-06584-0
dc.identifier.urihttps://hdl.handle.net/11424/286373
dc.identifier.volume47
dc.language.isoeng
dc.relation.ispartofARABIAN JOURNAL FOR SCIENCE AND ENGINEERING
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTemel Bilimler
dc.subjectNatural Sciences
dc.subjectÇOK DİSİPLİNLİ BİLİMLER
dc.subjectDoğa Bilimleri Genel
dc.subjectTemel Bilimler (SCI)
dc.subjectMULTIDISCIPLINARY SCIENCES
dc.subjectNATURAL SCIENCES, GENERAL
dc.subjectNatural Sciences (SCI)
dc.subjectMultidisciplinary
dc.subjectRecurrence plot (RP)
dc.subjectRecurrence plot quantification (RQA)
dc.subjectTracking failure
dc.subjectCable joints
dc.subjectComparative tracking index (CTI)
dc.subjectTracking characteristics
dc.subjectFAILURE
dc.titleThe application of recurrence plot in tracking characteristics of PU-Based insulation material
dc.typearticle
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
1.95 MB
Format:
Adobe Portable Document Format