Publication:
Radiation shielding performances of Na2SiO3 based low-cost micro and nano composites for diagnostic imaging

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Ltd

Research Projects

Organizational Units

Journal Issue

Abstract

The present study deals with determining the gamma-ray shielding parameters of the micro (μ)- Bi2O3, μ−WO3, nano (n)-Bi2O3, and n-WO3 reinforced Na2SiO3 (sodium metasilicate) composites experimentally and theoretically. The study has aimed to compare the size of reinforcing particles on the gamma-ray shielding ability of very low-cost and non-toxic Na2SiO3. In this context, the gamma-ray shielding performances of the samples containing different weight percentages of μ-Bi2O3, μ-WO3, n-Bi2O3, and n-WO3 particles have been evaluated by employing mass attenuation coefficient, half-value layer, and mean free path. The related parameters have been measured experimentally and also calculated by WinXCom. It has been revealed that Na2SiO3 composites having micro and nano-structured Bi2O3 and WO3 particles show good radiation shielding for 81 keV photons. In this respect, among all composites, the Na2SiO3/30% μ-WO3 sample has a promising potential to shield the ionizing radiation utilized in diagnostic imaging such as mammography, conventional X-ray machine, etc. © 2021

Description

Citation

Endorsement

Review

Supplemented By

Referenced By