Publication:
Comparison and validation of finite element analysis with a servo-hydraulic testing unit for a biodegradable fixation system in a rabbit model

dc.contributor.authorATALI, ONUR
dc.contributor.authorHARTOMACIOĞLU, SELİM
dc.contributor.authorsAtali, O.; Varol, A.; Basa, S.; Ergun, C.; Hartomacioglu, S.
dc.date.accessioned2022-03-13T12:45:42Z
dc.date.accessioned2026-01-10T20:28:08Z
dc.date.available2022-03-13T12:45:42Z
dc.date.issued2014
dc.description.abstractThe aim of this study was the biomechanical validation of three-dimensional finite element analysis (FEA) with a servo-hydraulic testing unit (STU) for a resorbable fixation system (RFS) in a rabbit model. Bilateral mandibular vertical body osteotomies (BMVBO) were performed in 15 female New Zealand rabbits. The animals were divided into three groups. The STU and FEA tests were done immediately after surgery in group 1 (1 day), at the first postoperative month in group 2, and at the third postoperative month in group 3. Both stress tests were carried out by applying vertical forces at the lower incisal edge, loading from 0 N force and increasing this until breakage occurred at the bone. The maximum forces that the hemimandibles could stand and the amount of deformation were recorded and analysed with the FBA and STU tests. We found the STU and FEA test results to be similar and that they could be used interchangeably for groups 1 and 3. However, the FEA results differed most from the real STU values in group 2 because of callus formation that had not ossified at the osteotomy line.
dc.identifier.doi10.1016/j.ijom.2013.06.007
dc.identifier.eissn1399-0020
dc.identifier.issn0901-5027
dc.identifier.pubmed23867254
dc.identifier.urihttps://hdl.handle.net/11424/237832
dc.identifier.wosWOS:000331672300006
dc.language.isoeng
dc.publisherCHURCHILL LIVINGSTONE
dc.relation.ispartofINTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectbiodegradable implant
dc.subjectbiomechanics
dc.subjectfinite element analysis
dc.subjectmandible
dc.subjectosteotomy
dc.subjectSPLIT RAMUS OSTEOTOMY
dc.subjectMANDIBULAR ANGLE FRACTURES
dc.subjectBIOMECHANICAL EVALUATION
dc.subjectORTHOGNATHIC SURGERY
dc.subjectSCREW FIXATION
dc.subjectTITANIUM PLATE
dc.subjectSTABILITY
dc.subjectMANDIBLES
dc.subjectIMPLANTS
dc.subjectSHEEP
dc.titleComparison and validation of finite element analysis with a servo-hydraulic testing unit for a biodegradable fixation system in a rabbit model
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage39
oaire.citation.issue1
oaire.citation.startPage32
oaire.citation.titleINTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY
oaire.citation.volume43

Files