Publication:
The Relationship between Digital Model Accuracy and Time-Dependent Deformation of Alginate Impressions

dc.contributor.authorsAlcan, Toros; Ceylanoglu, Cenk; Baysal, Bekir
dc.date.accessioned2022-03-14T08:33:31Z
dc.date.accessioned2026-01-11T10:25:04Z
dc.date.available2022-03-14T08:33:31Z
dc.date.issued2009-01-01
dc.description.abstractObjectives: To investigate the effects of different storage periods of alginate impressions on digital model accuracy. Materials and Methods: A total of 105 impressions were taken from a master model with three different brands of alginates and were poured into stone models in five different storage periods. In all, 21 stone models were poured and immediately were scanned, and 21 digital models were prepared. The remaining 84 impressions were poured after 1, 2, 3, and 4 days, respectively. Five linear measurements were made by three researchers on the master model, the stone models, and the digital models. Time-dependent deformation of alginate impressions at different storage periods and the accuracy of traditional stone models and digital models were evaluated separately. Results: Both the stone models and the digital models were highly correlated with the master model. Significant deformities in the alginate impressions were noted at different storage periods of 1 to 4 days. Alginate impressions of different brands also showed significant differences between each other on the first, third, and fourth days. Conclusions: Digital orthodontic models are as reliable as traditional stone models and probably will become the standard for orthodontic clinical use. Storing alginate impressions in sealed plastic bags for up to 4 days caused statistically significant deformation of alginate impressions, but the magnitude of these deformations did not appear to be clinically relevant and had no adverse effect on digital modeling. (Angle Orthod. 2009;79:30-36.)
dc.identifier.doi10.2319/100307-475.1
dc.identifier.issn0003-3219
dc.identifier.pubmed19123710
dc.identifier.urihttps://hdl.handle.net/11424/241969
dc.identifier.wosWOS:000262422200006
dc.language.isoeng
dc.publisherE H ANGLE EDUCATION RESEARCH FOUNDATION, INC
dc.relation.ispartofANGLE ORTHODONTIST
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDigital model
dc.subjectAlginate impression
dc.subject3Shape
dc.subjectDENTAL CASTS
dc.subjectPLASTER MODELS
dc.subjectTOOTH-SIZE
dc.subjectRELIABILITY
dc.subjectVALIDITY
dc.subjectSYSTEM
dc.titleThe Relationship between Digital Model Accuracy and Time-Dependent Deformation of Alginate Impressions
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage36
oaire.citation.issue1
oaire.citation.startPage30
oaire.citation.titleANGLE ORTHODONTIST
oaire.citation.volume79

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
file.pdf
Size:
192.7 KB
Format:
Adobe Portable Document Format