Publication:
Correlation analysis between surface electromyography and continuous-wave near-infrared spectroscopy parameters during isometric exercise to volitional fatigue

dc.contributor.authorÇOTUK, HASAN BİROL
dc.contributor.authorsSayli, Omer; Akin, Ata; Cotuk, Hasan Birol
dc.date.accessioned2022-04-25T00:10:49Z
dc.date.accessioned2026-01-10T19:34:48Z
dc.date.available2022-04-25T00:10:49Z
dc.date.issued2014
dc.description.abstractIn this study, the process of muscular fatigue was examined using surface electromyography (sEMG) and continuous-wave near-infrared spectroscopy (cw-NIRS) simultaneously during an isometric hand grip exercise at 50% and 75% of the maximal voluntary contraction (MVC), sustained until volitional fatigue. The mean frequency of the sEMG decreased during the whole exercise, whereas the root mean square had a tendency to increase. Oxyhemoglobin/deoxyhemoglobin concentration changes computed with cw-NIRS were found to exhibit a fast linear decrease/increase in the first 10-20 s of the exercise, the so-called fast phase, followed by a plateau-like slow phase. The change rates were higher at 75% MVC for both the sEMG and cw-NIRS parameters. Significant correlations were found, especially at 50% MVC, between the sEMG parameters computed for the whole exercise and cw-NIRS parameters computed from the early region of the exercise, i.e. infection duration and amplitude changes to the inflection point. The findings emphasize the potential of cw-NIRS for muscle studies.
dc.identifier.doi10.3906/elk-1210-51
dc.identifier.eissn1303-6203
dc.identifier.issn1300-0632
dc.identifier.urihttps://hdl.handle.net/11424/263776
dc.identifier.wosWOS:000332942900020
dc.languageeng
dc.publisherTUBITAK SCIENTIFIC & TECHNICAL RESEARCH COUNCIL TURKEY
dc.relation.ispartofTURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectFatigue
dc.subjectoxygenation
dc.subjectnear-infrared spectroscopy
dc.subjectsurface electromyography
dc.subjectisometric exercise
dc.subjectFLEXOR DIGITORUM SUPERFICIALIS
dc.subjectHUMAN SKELETAL-MUSCLE
dc.subjectMYOELECTRIC ACTIVITY
dc.subjectTISSUE OXYGENATION
dc.subjectLONG-DURATION
dc.subjectEMG
dc.subjectCONTRACTIONS
dc.subjectPHYSIOLOGY
dc.subjectTHRESHOLD
dc.subjectFOREARM
dc.titleCorrelation analysis between surface electromyography and continuous-wave near-infrared spectroscopy parameters during isometric exercise to volitional fatigue
dc.typearticle
dspace.entity.typePublication
oaire.citation.endPage793
oaire.citation.issue3
oaire.citation.startPage780
oaire.citation.titleTURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES
oaire.citation.volume22

Files