Publication: Correlation analysis between surface electromyography and continuous-wave near-infrared spectroscopy parameters during isometric exercise to volitional fatigue
| dc.contributor.author | ÇOTUK, HASAN BİROL | |
| dc.contributor.authors | Sayli, Omer; Akin, Ata; Cotuk, Hasan Birol | |
| dc.date.accessioned | 2022-04-25T00:10:49Z | |
| dc.date.accessioned | 2026-01-10T19:34:48Z | |
| dc.date.available | 2022-04-25T00:10:49Z | |
| dc.date.issued | 2014 | |
| dc.description.abstract | In this study, the process of muscular fatigue was examined using surface electromyography (sEMG) and continuous-wave near-infrared spectroscopy (cw-NIRS) simultaneously during an isometric hand grip exercise at 50% and 75% of the maximal voluntary contraction (MVC), sustained until volitional fatigue. The mean frequency of the sEMG decreased during the whole exercise, whereas the root mean square had a tendency to increase. Oxyhemoglobin/deoxyhemoglobin concentration changes computed with cw-NIRS were found to exhibit a fast linear decrease/increase in the first 10-20 s of the exercise, the so-called fast phase, followed by a plateau-like slow phase. The change rates were higher at 75% MVC for both the sEMG and cw-NIRS parameters. Significant correlations were found, especially at 50% MVC, between the sEMG parameters computed for the whole exercise and cw-NIRS parameters computed from the early region of the exercise, i.e. infection duration and amplitude changes to the inflection point. The findings emphasize the potential of cw-NIRS for muscle studies. | |
| dc.identifier.doi | 10.3906/elk-1210-51 | |
| dc.identifier.eissn | 1303-6203 | |
| dc.identifier.issn | 1300-0632 | |
| dc.identifier.uri | https://hdl.handle.net/11424/263776 | |
| dc.identifier.wos | WOS:000332942900020 | |
| dc.language | eng | |
| dc.publisher | TUBITAK SCIENTIFIC & TECHNICAL RESEARCH COUNCIL TURKEY | |
| dc.relation.ispartof | TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Fatigue | |
| dc.subject | oxygenation | |
| dc.subject | near-infrared spectroscopy | |
| dc.subject | surface electromyography | |
| dc.subject | isometric exercise | |
| dc.subject | FLEXOR DIGITORUM SUPERFICIALIS | |
| dc.subject | HUMAN SKELETAL-MUSCLE | |
| dc.subject | MYOELECTRIC ACTIVITY | |
| dc.subject | TISSUE OXYGENATION | |
| dc.subject | LONG-DURATION | |
| dc.subject | EMG | |
| dc.subject | CONTRACTIONS | |
| dc.subject | PHYSIOLOGY | |
| dc.subject | THRESHOLD | |
| dc.subject | FOREARM | |
| dc.title | Correlation analysis between surface electromyography and continuous-wave near-infrared spectroscopy parameters during isometric exercise to volitional fatigue | |
| dc.type | article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 793 | |
| oaire.citation.issue | 3 | |
| oaire.citation.startPage | 780 | |
| oaire.citation.title | TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES | |
| oaire.citation.volume | 22 |